Kucht CCAE48ASX Cheng Series 48 Inch Under Cabinet Ducted Hood with 1000 CFM Capable-Blower Sold Separately, Halogen Lights, Pro-Baffle Filters, Electronic Touch Controls, 3-Speed Fan in Stainless Steel

User Manual - Page 5

For CCAE48ASX.

PDF File Manual, 23 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Important Safety Notice
3
CAUTION
To reduce the risk of fi re and electric shock, install this range hood only with external blower models CBE-1000, rated
maximum 6.2 amps, 120V AC 60Hz or internal blowers manufactured by Zephyr Ventilation, models CBI-600A.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics,
crawl spaces or garages.
WARNING
TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITH AN ISOLATING WALL CONTROL/
SWITCH.
OPERATION
Always leave safety grills and fi lters in place. Without these components, operating blowers could catch onto hair, fi ngers
and loose clothing.
*NOTE: Please check www.zephyronline.com or call us for revisions before doing any custom work.
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customers responsibility:
- To contact a qualifi ed electrical installer.
- To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and
all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualifi ed electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualifi ed electrician if you are not sure the range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit
protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to
Electrical Diagram on product.
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase
and install appropriate connector if necessary.
Loading ...
Loading ...
Loading ...