Dri-Eaz F203-A 1200 Commercial Dehumidifier with Pump, Industrial, Durable, Compact,

User Manual - Page 4

For F203-A.

PDF File Manual, 18 pages, Read Online | Download pdf file

F203-A photo
Loading ...
Loading ...
Loading ...
remove the external drain hose, drain it carefully, and
return it to the pocket provided on the front of the unit.
MAINTENANCE
WARNING! ELECTRIC SHOCK HAZARD. Unplug the
1200 before performing any maintenance.
Before each use
Inspect the electrical cord for damage. Look for
fraying, cuts, etc. Do not use the unit if you find any
damage. Contact your local authorized distributor for
service.
Inspect and vacuum filter as needed. Keep a clean
filter in the unit at all times to protect internal
components from dust and other particulate build-up.
The 1200 is equipped with a 3M™ High Air-Flow filter.
The HAF filter may be vacuumed clean and reused up to
three times. Do not rinse or wash the HAF filter, as it
will reduce the effectiveness of the electrostatic material.
Replace only with a new 3M HAF Filter (Dri-Eaz part no.
F368). Contact your local authorized distributor for parts.
CAUTION: Dust can cause the unit to overheat and
shut down. Do not operate when excessive dust or
airborne particles are present, such as during
sanding or spray-painting. Inspect and clean air filter
elements and coils frequently.
IMPORTANT: Replace the HAF filter whenever 1)
it has been vacuumed clean 3 times or 2) it has
been used on a mold remediation job or
otherwise exposed to potentially dangerous
contaminants.
Monthly
Check coils. Dirty coils can cause the unit to overheat.
Clean when visibly dirty. See Fig. B.
1. Unplug unit.
2. Remove housing, locate coils and allow coils to dry if
wet.
3. Vacuum both sides of the coils until clean, being
careful not to let the nozzle touch the fins; as that may
cause damage by bending them.
Check catch basin tray. Clean when dirt and debris are
present.
1. Wipe clean with a rag.
Check drain hose.
1. Look for obstructions. Disconnect and clear any debris
present.
2. Reattach drain hose.
Annually
Have the pump system inspected by your local
authorized distributor.
TRANSPORT AND STORAGE
NOTICE: Handle the unit carefully. Do not drop, throw,
or place the unit where it could fall. Rough treatment can
damage this equipment and may create a hazardous
condition or void warranty.
IMPORTANT: Be sure to purge the water from the pump
reservoir before moving the unit. See the PURGE
function under "How to use the control panel" on page 2.
Note that the unit must be plugged in for the Purge
function to operate.
1. Do not expose the control panel to moisture, snow or
rain when transporting in uncovered vehicles.
2. Store and transport securely to avoid any damaging
impact to internal parts.
READ AND SAVE
THESE INSTR
ERROR MESSAGES
The table below shows error message that the system may detect. If the display shows an “ER” message, first unplug the
unit and then plug it back in. This may re-set the electronics, and if so, no further action is required. If the error message
reappears, try the solution shown under “Explanation.” If this still does not fix the problem, Contact your local authorized
distributor.
ERROR
MESSAGE
EXPLANATION
ER 1, 2, 3, 5, 6 Problem with electronic control panel. Contact Dri-Eaz Service.
ER 4 Check the temperature or sensor cable. Contact Dri-Eaz Service for instructions.
ER 8 Check the touchpad key. Press and release each key several times.
ER 9 Check for obstructions or kinks in the drain hose.
TROUBLESHOOTING
07-01705B 2014-04 Warranty 07-00420 4 Dri-Eaz Products, Inc.
Loading ...
Loading ...
Loading ...