Desktop Body Camera Dock Station User Manual
22
Chapter 8 Data Backup
Purpose:
When dock station software is abnormal or is re-installed, you can restore database.
8.1 Auto Backup
Step 1 Go to Settings > Data.
Step 2 Enable Auto-back.
Step 3 Set Auto-back Interval.
Step 4 Enter Backup to Keep value.
Backup to Keep: The upper limit of number of database backup file. Once exceeds the number,
the earliest database backup file will be replaced by the new one.
Step 5 Click Save. Go to installation root directory of dock station software >
BodyCamaraStationBackup folder to view the database backup file.
Figure 8-1 BodyCamaraStationBackup Folder