Model 88 V
Users Manual
66
Specifications
General Specifications
Maximum Voltage between any Terminal
and Earth Ground: ..................................................... 1000 V
W Fuse Protection for mA or µA inputs: ................ 44/100 A, 1000 V FAST Fuse
W Fuse Protection for A input:................................ 11 A, 1000 V FAST Fuse
Display: .......................................................................... Digital: 6000 counts updates 4/sec; (the Meter also has 19,999 counts in
high-resolution mode). Analog Bar Graph: 33 segments, updates
40/sec. Frequency: 19,999 counts, updates 3/sec at > 10 Hz.
Temperature: Operating:........................................... -20 °C to +55 °C; Storage: -40 °C to +60 °C
Altitude: ...................................................................... Operating: 2000 m; Storage:10,000 m
Temperature Coefficient: .......................................... 0.05 x (specified accuracy)/ °C (< 18 °C or > 28 °C)
Electromagnetic Compatibility: ................................ All ranges unless otherwise noted: In an RF field of 3 V/m total
accuracy = specified accuracy + 20 counts
Except: 600 UA dc range total accuracy = specified accuracy + 60
counts. Temperature not specified.
All ac ranges = specified accuracy + 70 counts.
Relative Humidity: ..................................................... 0 % to 90 % (0 °C to 35 °C); 0 % to 70 % (35 °C to 55 °C)
Battery Type:.............................................................. 9 V zinc, NEDA 1604 or 6F22 or 006P
Battery Life:................................................................ 400 hrs typical with alkaline (with backlight off)
Vibration: .................................................................... Per MIL-PRF-28800 for a Class 2 instrument
Shock:......................................................................... 1 Meter drop per IEC 61010-1:2001
Size (HxWxL):............................................................. 1.25 in x 3.41 in x 7.35 in (3.1 cm x 8.6 cm x 18.6 cm)