KSTAD110PD

Tarjeta de Registracion de Producto
Es sencillo! Cum pie y envia su Tarjeta de Registracion de Producto hoy!
N
o
m
br
e
I I I I I I I I I I I I I I I I I I I I I I I I I I I I
Direcci6n
I I I I I I I I I I I I I I I I I I I I I I I I I I I I
Ciudad
I I I I I I I I I I I I I I
I
Estado
�
��\i�
I I I I I I
leno (Opcional) / - I I I I I
Dir
eccion de E-mail (Opcional) �----------�
Donde Comprado
I I I I I I I I I I
I I I I I I I I I I
I
Numero de Modelo
Nume de Serie
REV11/04
Mes
Dia
Ano
Fecha de la mp
Product Registration Card
It's simple! Complete and mail your Product Registration Card today!
N
a
m
e
I I I I I I I I I I I I I I I I I I I I I I I I I I I I
A
ddress! I I I I I I I I I I I I I I I I I I I I I I I I I I I
city I I I I I I I I
I I I I I I I
state Zip
I
I I I I I
Phone (Optional) / - I I I I I
E-mail Address (Optional)
�----------�
Where Purchased
I I I I I I I I I I
I I I I I I I I
I I
Model Number
Serial Number
REV11/04
Month Day Year
Date of Puase

3�3H
dVS
3Vld
·aHl
S
Od
JadOJd1nm
M
J8A!18P I
O
U
ll!
M8
!QI
S
0d
·paJ1nba
a6e1sod
l•11
1
1•11
1
1
1
1•1
111
11
1
••
1
•1
1
•
1
1•1••••
1
•11l•1••l••l11•
1
1
•11•
11
•11ll
11 111
Product Warranty Card
Tarjeta de Garantia de Producto
Air conditioner warranty
Your product is protected by this warranty:
ur appliance is warranted by Keystone. Any obligations r services and parts under this warranty
must be performed Keystone.
contact a Customer Service Representative.Call TOLL FREE
800-849-1112
Su producto esta protegido par esta garantia:
Su producto esta garantizado par Keystone. Cualquier obligaci6n de proporcionar servicio o
repuestos establecida en esta garantia deberi ser cumplida par las Seicios al consumidor de
Keystone.
Para comunicarse con un Representante de Seicio al Cliente, tenga la bondad de Ila mar par tel0fono
sin cargo alguno a, al nUmero:
800-849-1112

4
1. BEFORE YOU BEGIN......................................................................................5
2. FOR YOUR SAFETY........................................................................................9
3. PRODUCT OVERVIEW....................................................................................15
4. INSTALLATION...............................................................................................19
5. OPERATION..................................................................................................22
6. CLEANING AND CARE...................................................................................26
7. TROUBLE SHOOTING....................................................................................28
8. DECOMMISSIONING.....................................................................................30

5
1. BEFORE YOU BEGIN
1.1 PRODUCT DESCRIPTION
The dehumidifier is used to remove excessive moisture from the air. The
resulting reduction in relative humidity protects buildings and their contents
from the adverse effects of excess humidity.
The environmentally friendly R32 is used as the refrigerant. R32 has no
damaging influence on the ozone layer (ODP), a negligible greenhouse effect
(GWP) and is available worldwide. Because of its efficient energy properties,
R32 is highly suitable as a coolant for this application. Special precautions must
be taken into consideration due to the coolant's high flammability.

6
1.2 SYMBOLS FROM THE UNIT AND USER MANUAL
warning
This unit uses a flammable refrigerant.
If refrigerant leaks and comes in contact with fire or heating
part, it will create harmful gas and there is risk of fire.
Read the USER MANUAL carefully before operation.
Further information is available in the USER MANUAL,
SERVICE MANUAL, and the like.
Service personnel are required to carefully read the USER
MANUAL and SERVICE MANUAL before operation.

7
THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
This appliance is intended to be used by expert or trained users in
shops, in light industry and on farms, or for commercial use by
lay persons.
This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without
supervision.
The unit is designed only for use with R32(propane) gas as the
designated refrigerant.
The refrigerant loop is sealed. Only a qualified technician should
attempt to service!
Do not discharge the refrigerant into the atmosphere.
R32 (propane) is flammable and heavier than air.
It collects first in low areas but can be circulated by the fans.
If propane gas is present or even suspected, do not allow
untrained personnel to attempt to find the cause.
The propane gas used in the unit has no odor.
The lack of smell does not indicate a lack of escaped gas.
If a leak is detected, immediately evacuate all persons from the
store, ventilate the room and contact the local fire department
to advise them that a propane leak has occurred.
Do not let any persons back into the room until the qualified
service technician has arrived and that technician advises that
it is safe to return to the room.
No open flames, cigarettes or other possible sources of ignition

8
should be used inside or in the vicinity of the units.
Component parts are designed for propane and non-incentive
and non-sparking. Component parts shall only be replaced with
identical repair parts.
FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN
EXPLOSION, DEATH, INJURY AND PROPERTY DAMAGE.

9
2. FOR YOUR SAFETY
Your safety is the most important thing we concerned!
2.1 OPERATIONAL PRECAUTIONS
WARNING- to reduce the risk of fire, electric shock or injury to
persons or property:
If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
The appliance shall be disconnected from its power source during
service.
Always operate the unit from a power source of equal voltage,
frequency and rating as indicated on the product identification plate.
Always use a power outlet that is grounded.
Unplug the power cord when cleaning or when not in use.
Do not operate with wet hands. Prevent water from spilling onto the
unit.
Do not immerse or expose the unit to rain, moisture or any other liquid.
Do not leave the unit running unattended. Do not tilt or turn over the
unit.
Do not unplug while the unit is operating.
Do not unplug by pulling on the power cord.
Do not use an extension cord or an adapter plug.
WARNING
Please read this manual carefully and fully
understand before operating your appliance.

10
Do not put objects on the unit.
Do not climb or sit on the unit.
Do not insert fingers or other objects into the air outlet.
Do not touch the air inlet or the aluminum fins of the unit.
Do not operate the unit if it is dropped, damaged or showing signs of
product malfunction.
Do not clean the appliance with any chemicals.
Ensure the unit is far away from fire, inflammable, or explosive objects.
The unit shall be installed in accordance with national wiring
regulations.
Do not use means to accelerate the defrosting process or to clean, other
than those recommended by the manufacture.
The appliance shall be stored in a room without continuously operation
sources (for example: open flames, an operating gas appliance or an
operating electric heater).
The appliance shall be stored so as to prevent mechanical damage from
occurring.
Do not piece or burn, even after use.
Be aware that refrigerants may not contain an odour.
Pipe-work shall be protected from physical damage and shall not be
installed in an unventilated space, if that space is smaller than 8 m².
Compliance with national gas regulations shall be observed.
Keep any required ventilation openings clear of obstruction.
The appliance shall be stored in a well-ventilated area where the room
size corresponds to the room area as specified for operation.

11
WARNING
Any person who is involved with working on or breaking
into a refrigerant circuit should hold a current valid
certificate from an industry-accredited assessment
authority, which authorizes their competence to handle
refrigerants safely in accordance with an industry,
recognized assessment specification.
WARNING
Servicing shall only be performed as recommended by the
equipment manufacturer. Maintenance and repair
requiring the assistance of other skilled personnel shall be
carried out under the supervision of the person
competent in the use of flammable refrigerants.
If you don't understand something or need help, please contact the dealer
services.

12
2.2 SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when
servicing an appliance with R32.
2.2.1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants,
safety checks are necessary to ensure that the risk of ignition is minimized.
For repair to the refrigerating system, the following precautions shall be
complied with prior to conducting work on the system.
2.2.2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimize
the risk of a flammable gas or vapor being present while the work is being
performed.
2.2.3 General work area
All maintenance staff and others working in the local area shall be
instructed on the nature of work being carried out. Work in confined spaces
shall be avoided. The area around the work space shall be sectioned off.
Ensure that the conditions within the area have been made safe by control
of flammable material.
2.2.4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to
and during work, to ensure the technician is aware of potentially flammable
atmospheres. Ensure that the leak detection equipment being used is
suitable for use with flammable refrigerants, i.e. no sparking, adequately
sealed or intrinsically safe.
2.2.5 Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any
associated parts, appropriate fire extinguishing equipment shall be available
to hand. Have a dry powder or CO2 fire extinguisher adjacent to the
charging area.

13
2.2.6 No ignition sources
No person carrying out work in relation to a refrigeration system which
involves exposing any pipe work that contains or has contained flammable
refrigerant shall use any sources of ignition in such a manner that it may
lead to the risk of fire or explosion. All possible ignition sources, including
cigarette smoking, should be kept sufficiently far away from the site of
installation, repairing, removing and disposal, during which flammable
refrigerant can possibly be released to the surrounding space. Prior to work
taking place, the area around the equipment is to be surveyed to make sure
that there are no flammable hazards or ignition risks. “No Smoking” signs
shall be displayed.
2.2.7 Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before
breaking into the system or conducting any hot work. A degree of
ventilation shall continue during the period that the work is carried out. The
ventilation should safely disperse any released refrigerant and preferably
expel it externally into the atmosphere.
2.2.8 Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the
purpose and to the correct specification. At all times the manufacturer’s
maintenance and service guidelines shall be followed. If in doubt consult
the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable
refrigerants:
– The charge size is in accordance with the room size within which the
refrigerant containing parts are installed;
– The ventilation machinery and outlets are operating adequately and are
not obstructed;
– If an indirect refrigerating circuit is being used, the secondary circuit shall
be checked for the presence of refrigerant;
– Marking to the equipment continues to be visible and legible. Markings
and signs that are illegible shall be corrected;

14
– refrigeration pipe or components are installed in a position where they are
unlikely to be exposed to any substance which may corrode refrigerant
containing components, unless the components are constructed of
materials which are inherently resistant to being corroded or are suitably
protected against being so corroded.
2.2.9 Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety
checks and component inspection procedures. If a fault exists that could
compromise safety, then no electrical supply shall be connected to the
circuit until it is satisfactorily dealt with. If the fault cannot be corrected
immediately but it is necessary to continue operation, an adequate
temporary solution shall be used. This shall be reported to the owner of the
equipment so all parties are advised.
Initial safety checks shall include:
-those capacitors are discharged: this shall be done in a safe manner to
avoid possibility of sparking;
-that there no live electrical components and wiring are exposed while
charging, recovering or purging the system;
-that there is continuity of earth bonding.
WARNING!
Install the unit in rooms which exceed 8 m².
Do not install the unit in a place where inflammable gas may
leak.
NOTE!
The manufacture may provide other suitable example or may
provide additional information about the refrigerant odour.

15
3. PRODUCT OVERVIEW
3.1 SPECIFICATIONS
Model Number
KSTAD110PD
Power supply
AC 115V / 60Hz
Rated capacity
45Pints/Day @ 65˚F, 60% RH
70Pints/Day @ 80˚F, 60% RH
120Pints/Day @ 86˚F, 80% RH
160Pints/Day @ 95˚F, 90% RH
Power Consumption & Current
532W/4.7A @ 65˚F, 60% RH
660W/5.8A @ 80˚F, 60% RH
780W/6.8A @ 86˚F, 80% RH
930W/8.1A @ 95˚F, 90% RH
Noise
≤60dB(A)
Air Circulation
265 CFM
Refrigerant Type
R32
Water tank capacity
1.45 Gallon
Net Weight
80 lb
Gross Weight
88 lb
Dimension(WxDxH)
21.3'' x 16.8'' x 35.2''

16
3.2 PACKAGE CONTENTS
Item
Description
Quantity
120Pints industrial
dehumidifier
1 unit
Spare water tank plug
1 pcs
Handle quick fixing bolts
Diameter: 0.24’’
Length: 1.6’’
2 pcs
PVC drain hose
Length: 16.4’
Inner diameter: 0.32’’
1 pcs

17
Drain Hose
Pushing Handle
Big Wheel
3.3 PRODUCT DIAGRAM
Front
Control panel
Air Inlet
Water tank cover

18
Back
Note: The appearance is only for reference. Please see the real product for
detailed information.
Power Cord Wrap
Radiator Grille
Air Outlet
Side Handle
Caster(with brake)

19
4. INSTALLATION
4.1 Handle Installation

20
4.2 Drainage Installation
Install the included drain hose to the draining nozzle on the machine and
direct the hose to the desired area before operate the machine.
If the drain area is located above the dehumidifier, the maximum capacity of
the water pump is 16.4ft. If the water is drained downwards, there is no limit
for the distance.
Press and hold DRAIN button to drain the water manually. The water pump
will work for 35 seconds before stopping. Repeat until all water is drained.
Drain the water manually before storing or moving the unit.
WARNING: Do not block the drainage hose. The end of the drainage pipe should
not be higher than the outlet hole. If the drainage pipe end is higher than the
outlet hole, water will not drain properly and could damage components of the
unit.

21
4.3 LOCATION
1. Place the appliance on a firm and horizontal surface.
2. Never install the appliance at a place that could be subject to:
● Heat sources such as radiators, heat registers, stoves or other
products that produce heat.
● Possible splashing of oil or water
● Direct sunlight
● Mechanical vibration or shock
● Excessive dust
● Lack of ventilation, such as cabinet or bookcase
● Uneven surface

22
5. OPERATION
5.1 Button Function
POWER
Press this button to turn the unit on/ off. The screen will light up to
show the current ambient humidity level when the unit is on. The
default setting for mode and humidity level are: continuous and
50%.
NOTE: The pump will keep operating if it hasn’t finished draining
when the unit is turned off, and will shut down after it finishes.
TIMER
The first press of this button will turn the timer on, and the timer
indicator will light up. Press the “ADD” or “MINUS” button to
increase or decrease the timer within a 24 hour time frame.
In the power-on state, the timer indicates the length of operation
time.
In the standby state, the timer indicates the length of time until

23
the reserved turning-on time. The timer is memoryless, so it needs
to be reset each time.
Press this button for 3 seconds to show current temperature. After
10 seconds, the display will return to show current humidity.
MINUS
Each press of this button will decrease the set humidity level/timer
by 5 %/1 hour within the range of 20-90%/0-24 hours.
ADD
Each press of this button will increase the set humidity level/timer
by 5 %/1 hour within the range of 20-90%/0-24 hours.
CONT
In the intelligent dehumidification mode, press this button to
switch to the continuous dehumidification mode. The set humidity
level is unadjustable under this mode, and the machine will
operate continuously regardless of the ambient humidity level.
In the continuous dehumidification mode, press this button to
switch to the intelligent dehumidification mode, where the set
humidity level is adjustable.
DRAIN
Press this button to activate pump drainage. The pump will
operate for 35 seconds and automatically turn off.

24
NOTE:
● The dehumidifier starts operating in the mode that it was last in.
● The dehumidifier starts dehumidifying if the room humidity level is 3%
higher than the set humidity level, and stops if the room humidity level is
3% lower than the set humidity level.
5.2 INDICATORS
: Water Full Indicator
: Continuous Mode Indicator
: Defrosting Indicator
: Timer Indicator
5.3 Operation
1) When the water pump is full, the “FULL” light goes on red and alarm goes on
after 5 seconds. Buzzer beeps 15 times and the compressor and fan shut off.
After the water pump is emptied, the machine will automatically switch to the
previous mode while the compressor will be in 3 minutes of self-protect. Alarm
will stop in 3 seconds after the water pump is emptied, fan starts, and
compressor will start in 3 minutes.
2) Compressor will not need 3 minutes for self-protect if it was the first time to
start the machine, press “POWER” and power off; power on, press “POWER”,
compressor starts immediately.
3) The system has auto memory. When all the mode setting has been finished, if
there is sudden power cut during operation, or the power jack slips out, the
system may store the current status before the power is cut and enter the
operation mode before power cut automatically after power is supplied.

25
5.4 Defrost Function
1) The compressor and fan will shut off when the environmental temperature goes
below 41 °F or above 100.4°F.
2) During defrosting, if power is off or shut down, it needs to start defrosting again
after the power comes in or starts up. The dehumidification mode can work
properly only after the defrosting is completed.
Note: During defrost, light won’t be off until the defrosting is over.

26
6. CLEAN AND CARE
6.1 CLEANING
1. Body Cleaning
Use a soft and slightly moist cloth to clean the dehumidifier ’s body. Do not use
cleanser, steel balls, chemically treated dust-proof cloth, gasoline, benzene,
thinners, or other chemical solvents in case of damage or distortion.
WARNING: Before cleaning or conducting maintenance, please turn off and unplug
the machine to avoid the risk of electrocution
2. Filter Cleaning (every 2 weeks)
● Pull to open the dehumidifier’s back panel, and slide the filter upward to
take it out from the panel.
● Use a vacuum cleaner to gently absorb the dust on the filter’s surface.
● If the filter is dirty, wash it with water and a soft detergent, and dry it
thoroughly afterwards.
● Put the filter back in the back panel, and close the dehumidifier ’s back
panel.

27
WARNING: It is strongly advised to rinse the filter every two weeks. Any dust
blocking the filter will potentially affect the machine’s functionality.
6.2 CLEANING UP OF REFRIGERANT
General Measures:
1. Gas/vapor heavier than air. May accumulate in confined spaces, particularly at
or below ground level.
2. Eliminate every possible source of ignition.
3. Use appropriate personal protection equipment (PPE).
4. Evacuate unnecessary personnel, isolate, and ventilate area.
5. Do not get in eyes, on skin, or on clothing. Do not breathe vapors or gas.
6. Prevent entry to sewers and public waters.
7. Stop the source of the release, if safe to do so. Consider the use of water
spray to disperse vapors.
8. Isolate the area until gas has dispersed. Ventilate and gas test area before
entering. Contact competent authorities after a spill.

28
7. TROUBLE SHOOTING
1. Functioning Temperature: 41℉ ≤ Ambient Temperature ≤ 95℉
When the ambient temp is lower or higher than the functioning temp, the
dehumidifier stops functioning.
When 41 ℉ ≤ Ambient temperature ≤ 61 ℉ , the compressor
automatically defrosts at intervals; during defrosting, the compressor stops
and the fan keeps running.
2. Before Calling for Service
Before contacting the customer service, please review the following
troubleshooting list that includes common problems that are not the result
of a defect in workmanship or materials.
trouble
cause
solution
Not operating
Unit is not plugged in.
Plug in the unit.
Room temperature is
under 41℉ or above 95
℉.
To protect the machine, use it
only when ambient temperature
is between 41℉ and 95℉.
Humidity level not
dropping
When the humidity set
point is 2% higher than
the ambient humidity
level.
Reset the humidity to a lower set
point, or power the machine off
if the ambient humidity level
already satisfies you.
Reduced
dehumidifying
capacity
Filter jammed.
Clean the filter as instructed.
Air-in and/or Air-out
louvers jammed.
Clear the blockage from Air-in
and/or Air-out louvers.

29
No air inlet
Filter or air-in louver
jammed.
Clean the filter as instructed or
clean the louver blockage.
Loud noise
Machine tilted.
Move it to a flat ground.
Filter jammed.
Clean the filter as instructed.
Error Code ‘E1’
Temperature sensor
problem
Change the sensor
Error Code ‘E2’
Humidity sensor problem
Change the sensor
WARNING:
If the Water Full indicator is always on, there may be a malfunction in the
machine. Please seek technical support from professionals.
If anything unexpected happens, please turn off and unplug the machine
immediately, and seek technical support from certified electrical engineers.

30
8. DECOMMISSIONING
8.1 STORAGE
Long-Term Storage - If you will not be using the unit for an extended period
of time (more than a few weeks) it is best to clean the unit and dry it out
completely. Please store the unit per the following steps:
1.Unplug the unit and remove exhaust hose and window kit store with the
unit.
2.Drain the remaining water from the unit.
3.
Clean the filter and let the filter dry completely in a shaded area.
4.Re-install the filter at its position.
5.The unit must be kept in upright position when in storage.
6.
Preserving the machine in ventilating, dry, non- corrosive gas and safe
place indoor.
ATTENTION:
The evaporator inside the machine has to be dried out before the unit is packed to
avoid component damage and molds. Unplug the unit and place it in a dry open area
for days to dry it out. Another way to dry the unit is turn on the machine, adjust it to
low-wind ventilation mode, and maintain this state until the drainage pipe becomes
dry, so as to keep the inside of the body in a dry state and prevent it from mildewing.

31
8.2 DISPOSAL
Do not dispose of electrical appliances as
unsorted municipal waste, use separate
collection facilities. Contact your local
government for information regarding the
collection systems available. If electrical
appliances are disposed of in landfills or dumps,
hazardous substances can leak into the
groundwater and get into the food chain,
damaging your health and well-being.
WARNING!!!
Releasing refrigerant into atmosphere is strictly
forbidden!