Hikvision DS-2TD5537T-7/W Bi-spectrum Thermography Mini Positioning Series

User Manual - Page 24

For DS-2TD5537T-7/W.

PDF File Manual, 128 pages, Read Online | Download pdf file

DS-2TD5537T-7/W photo
Loading ...
Loading ...
Loading ...
Thermal & Optical Bi-spectrum PTZ Network Camera User Manual
9
Note
The settings vary according to different camera models.
Reflect Light Filter & Forklift Filter are mutually exclusive with VCA functions.
The filtering status will be displayed on the lower right of the interface.
4. Click Save.
3.3.2 Set Normal Mode
This function is used to measure the temperature of the whole scene and alarm.
Steps
1. Go to Configuration → Temperature Measurement → Basic Settings, and check Enable
Temperature Measurement.
2. Refer to Set Thermography Parameters to set the parameters.
3. Go to Configuration → Temperature Measurement → Advanced Settings, and select Normal.
4. Configure the parameters of normal mode.
Emissivity
Set the emissivity of your target. The emissivity of each object is different.
Distance
The distance between the target and the device.
Pre-Alarm Threshold
When the temperature of target exceeds the pre-alarm threshold, and this status keeps more
than Filtering Time, it triggers pre-alarm.
Alarm Threshold
When the temperature of target exceeds the alarm threshold, and this status keeps more
than Filtering Time, it triggers alarm.
Pre-Alarm Output and Alarm Output
Check Pre-Alarm Output and Alarm Output to link the pre-alarm or alarm with the connected
alarm device.
5. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for
setting linkage method.
6. Click Save.
The maximum and minimum temperature will be displayed on the live view.
Note
Go toImage → VCA Rules Display to adjust the fonts size and the temperature colour of normal,
alarm and pre-alarm.
Loading ...
Loading ...
Loading ...