URC LT-3301-RD Red Dimmer or Switch Paddle

LT-3300 Owner's User Manual - Page 6

For LT-3301-RD.

PDF File Manual, 10 pages, Read Online | Download pdf file

LT-3301-RD photo
Loading ...
Loading ...
Loading ...
LT-3300 Dimmer/Switch
6
Single-Pole Installation (Single Dimmer/Switch) - Neutral Wire
The LT-3300 can be used in a 3-way/4-way lighting
installation.
The Master Load Controller must be dened in
URC software.
Secondary controllers must be dened in URC
software.
Multi-Way will not work without prior programming.
Traveler Wire is not needed for Multi-Way
installation of two or more LT-3300s.
3-Way Installation (Line/Load in Same Box)
Load
Line/Hot
Neutral
Traveler
Romex Cable
Ground
Wire Key
Use two or more LT-3300s for the best
possible user experience.
!!
URC RECOMMENDATION
Wiring Instructions: Neutral Installation
Please use the following wire diagram if you have a neutral wire. Terminal screw torque: 0.8(7.08) N•m (lbf-in). For non-
neutral installations, more wiring diagrams and information please visit: www.urc-automation.com/roducts/lt-3300