7
3.3 Automatic Thermography
Configure the temperature measurement parameters and temperature measurement rules. The
device can measure the actual temperature and output alarms when temperature exceeds the
alarm threshold value.
3.3.1 Set Thermography Parameters
Configure the parameters of temperature measurement.
Steps
1. Go to Configuration Local, enable Display Temperature Info. .
Display Temperature Info.
Select Yes to display temperature information on live view.
Enable Rules to display the rules information on live view.
2. Click Save.
3. Go to Configuration Temperature Measurement Basic Settings to configure parameters.
Enable Temperature Measurement
Check to enable temperature measurement function.
Enable Color-Temperature
Check to display Temperature-Color Ruler in live view.
Display Temperature Info. on Stream
Check to display temperature information on the stream.
Display Temperature in Optical Channel
Check to display thermal channel temperature information in the optical channel.
Display Max./Min./Average Temperature
Check to display maximum/minimum/average temperature information on live view when
the temperature measurement rule is line or area.
Position of Thermometry Info
Select the position of temperature information showed on the live view.
Near Target: display the information beside the temperature measurement rule.
Top Left: display the information on the top left of screen.
Unit
Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin (K).
Temperature Range
Select the temperature measurement range.
Optical Transmissivity
Set the optical transmissivity of external optical material (e.g.: germanium window) to