15OPERATING INSTRUCTIONS
There is a 2-Second delay for the
compressor shutting down when selecting
FAN ONLY. This is to cover the possibility of
having to roll through to select another
mode.
The control will maintain the set
temperature within 2 degrees Fahrenheit,
between 60°F and 90°F degrees.
After a power outage, the unit will memorize
the last setting and return the unit to the
same setting once power is restored.
Now that you have mastered the operating
procedure, here are more features in your
control that you should become familiar with.
ADDITIONAL THINGS YOU SHOULD KNOW
NOTE
The "Cool" circuit has an automatic 3
minutes time delayed start if the unit is
turned o and on quickly. This prevents
overheating of the compressor and possible
circuit breaker tripping. The fan will
continue to run during this time.
Fresh Air Vent Control (on some models)
The Fresh Air Vent allows the air conditioner
to:
1. Recirculate inside air - Vent Closed (see
Fig. 1)
2. Draw fresh air into the room - Fresh Air
(see Fig. 2)
3. Exchange air from the room - Vent Open
(see Fig. 3)
Figure 1 (VENT CLOSED)
The unit should be operated in a
temperature range of indoor side 60°F -
90°F (16°C - 32°C), outdoor side 64°F -
109°F (18°C - 43°C). Performance may be
reduced outside of these operating
temperatures.
Note: There are more than 3 error codes. If an error code appears on the display, turn o the
unit and restart it. If the error code persist, please contact your Frigidaire Customer Service
Center 1-800-944-9044(US) / 1-800-265-8352 (Canada).
FAULT CODES:
Error Code Description
EH00
Internal memory chip failure
If any of the below error codes show on the display, please contact your Frigidaire Customer
Service Center 1-800-944-9044(US) / 1-800-265-8352 (Canada).
EH60
Indoor ambient temperature sensor is open/short circuited
EH0b
Communication malfunction of main control board.
Note: The error codes will be separated into 2 parts. The display will alternate in 1 second
intervals. For example, if the fault code "EH00" occurs, the panel will first display "EH" for 1
second, then display "00" for another second. The error code will continue to loop until the
issue is resolved.
SHOWS “EH” FOR ONE SECOND: THEN SHOWS “00” FOR ANOTHER SECOND: