7
2
VGA
DB9 connector for VGA output. Display local video
output and menu.
3
LAN1/LAN2
2 RJ-45 10/100/1000 Mbps self-adaptive Ethernet
interfaces.
4
Audio input/output
RCA connector for audio input/ output.
5
HDMI1 and HDMI2
HDMI video output connector.
6
USB 3.0 interface
Four Universal Serial Bus (USB) 3.0 ports for
additional devices such as USB mouse and USB Hard
Disk Drive (HDD).
7
RS-485 and terminal
switch
RS-485 interface and terminal switch.
8
Alarm input/output
(optional)
Connector for alarm input/output.
9
GND
Ground (needs to be connected when NVR starts
up).
10
100 to 240 VAC
100 to 240 VAC power supply.
11
Power switch
Switch for turning on/off the device.
12
PoE interface
Network interfaces for the cameras and to provide
power over Ethernet. Only available for
DS-WSELI-T2/8P and DS-WSELI-T4/16P. 8 interfaces
for DS-WSELI-T2/8P and 16 interfaces for
DS-WSELI-T4/16P.