Sensivity
Sensivity stands for the percentage of the body part of an acceptable target that enters the
predened region. Sensivity = 100 - S1/ST × 100. S1 stands for the target body part that goes
across the predened region. ST stands for the complete target body. The higher the value of
sensivity is, the more easily the alarm can be triggered.
Threshold
The threshold for the me of the objects removed from the region. If you set the value as 10,
alarm is triggered aer the object disappears from the region for 10s.
6.
Oponal: Repeat the above steps to set more regions.
7.
For the arming schedule sengs, see Set Arming Schedule . For the linkage method sengs, see
Linkage Method Sengs .
8.
Click Save.
Note
The funcon is only supported by certain models. The actual display varies with the models.
6.2.9 Draw Area
This secon introduces the conguraon of area.
Steps
1.
Click Detecon Area.
2.
Click on the live view to draw the boundaries of the detecon region, and right click to complete
drawing.
3.
Click Save.
Note
Click Clear to clear the selected area.
Click Clear All to clear all pre-dened areas.
6.2.10 Set Size Filter
This part introduces the seng of size lter. Only the target whose size is between the minimum
value and maximum value is detected and triggers alarm.
Steps
1.
Click Max. Size, and drag the mouse in the live view to draw the maximum target size.
2.
Click Min. Size, and drag the mouse in the live view to draw the minimum target size.
3.
Click Save.