www.factorybuysdirect.com
5200376-01B
SPECIFICATIONS
Model FDLT24/30-1
Ignition Electronic Piezo Ignitor
Gas Type Natural Gas Propane Gas
Maximum Input Rating
33,000 Btu/Hr 33,000 Btu/Hr
Minimum Input Rating
25,000 Btu/Hr 20,000 Btu/Hr
Manifold Pressure 4" W.C. 9" W.C.
Inlet Gas Pressure* (inches
of water) (*for purposes of
input adjustment)
Max. 9.5" Max. 14"
Min. 5" Min. 11"
PRODUCT FEATURES
This log set has been tested and approved to
ANSI Z21.11.2 standard for Unvented Heat-
ers and can be operated with the ue damper
closed. State and local codes in some areas
prohibit the use of vent-free heaters.
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot shuts off the heater if there is not
enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic
piezo control system. This system requires a
AAA battery (provided).
THERMOSTAT HEAT CONTROL
The control automatically cycles the burner
on and off to maintain a desired room
temperature.
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either
propane or natural gas. The heater is shipped
from the factory ready for connecting to pro-
pane. The heater can easily be changed to
Natural gas by having your qualied installer
follow the instructions on page 13 and the
markings on the heater.
PRODUCT IDENTIFICATION
*For purposes of input adjustment
Figure 1 - Vent-Free Log Chassis
Ignitor Button
Control Knob
Burner
Pilot