SPT SD-71E 70 pints Dehumidifier

INSTRUCTION MANUAL - Page 10

For SD-71E.

PDF File Manual, 11 pages, Read Online | Download pdf file

SD-71E photo
Loading ...
Loading ...
Loading ...
9
TECHNICAL SPECIFICATIONS
MODEL SD-31E SD-41E SD-61E SD-71E
Moisture Removal ** 30 pints per day
40 pints per day
60 pints per day
70 pints per day
Power Supply 115V / 60Hz
Current 3.0A 4.5A 4.9A 6.9A
Power Consumption 310W 450W 550W 720W
Energy Factor (EEV) 1.85 L/kWh
Starting Current 14A 21A 28A 33A
41 ~ 95°F
Working Environment
35% to 85% RH
Water Tank Capacity 3L 6L
Air Flow (High//Low) 245/210 m3/h 320/280 m3/h
Noise Level (High) 56 dB(A) 58.5 dB(A)
Dimension 14.17(W) x 10.24(D) x 19.88(H) in. 15.35(W) x 10.98(D) x 23.15(H) in.
Net/Gross Weight 29/31 lbs 30/32 lbs 40/42 lbs
** Capacity will vary according to actual room ambient temperature and humidity conditions.
TROUBLE SHOOTING
BEFORE COTACTING THE MANUFACTURER, PLEASE CHECK THE FOLLOWING
POSSIBILITIES.
PROBLEM CHECK
Unit fails to start
Power is OFF or power cord is unplugged/not securely fitted.
Water bucket is not placed properly
Water bucket is full or set humidity has been reached
Check power to the outlet, fuse/circuit breaker box
Performance decreased
Blocked air filter
Room windows and doors are open
Obstacles in air outlet or inlet
Not enough time allowed to remove the moisture
Humidity setting may be set too high
Ambient temperature is too cold, below 41°F
Unit is noisy
Unstable setting of unit or floor surface is not level
Blocked filter
Frost appears on coils
This is normal. The dehumidifier has Auto-Defrost feature
Water on floor
Hose connection for continuous drainage is loose
Intend to use the bucket for water collection, but the drain plug is removed.
ES, AS P2 and EC
appears in display
Refer to error codes on page 4.
Unit is not collecting as
much water during the
winter months
When temperature is low, absolute humidity level will drop as well, even
when relative humidity is at the same percentage. There is less water
vapor in the air when temperature is low
Difficulty inserting the
continuous drain tube
Soak the plastic white connector in hot water for a few minutes will soften
the plastic and make it easier to connect.
If you still cannot solve the problem after trying the above, unplug unit and contact Sunpentown Int’l Inc.
Loading ...