Stiebel Eltron TEMPRA 24 PLUS 224199 240V, 1 Phase, 50/60 Hz, 24 kW Whole House

OPERATION AND INSTALLATION - Page 8

For TEMPRA 24 PLUS.

PDF File Manual, 32 pages, Read Online | Download pdf file

TEMPRA 24 PLUS photo
Loading ...
Loading ...
Loading ...
– 8 –
!
NOTICE: THIS UNIT SHOULD NOT BE INSTALLED IN A
LOCATION WHERE IT MAY BE EXPOSED TO FREEZING
TEMPERATURES (LESS THAN 36 °F). IF THE UNIT MAY
BE SUBJECT TO FREEZING TEMPERATURES ALL WATER
MUST BE DRAINED FROM THE UNIT. FAILURE TO COMPLY
WITH THIS INSTRUCTION VOIDS ALL WARRANTIES.
THE UNIT SHOULD BE LOCATED IN AN AREA WHERE
WATER LEAKAGE FROM THE UNIT OR CONNECTIONS
WILL NOT RESULT IN DAMAGE TO THE AREA ADJACENT
TO THE UNIT. IF SUCH A LOCATION CANNOT BE AVOIDED
IT IT RECOMMENDED THAT A DRAIN PAN BE INSTALLED
UNDER THE UNIT.
1. Install TEMPRA as close as possible to the main hot water draw-
off points.
2. Install TEMPRA in a frost free area. If frost might occur, remove
unit before freezing temperatures set in.
3. Leave a minimum of 5" of clearance on all sides for servicing.
4. Remove the cover screw with chopper disc and open the cover
C
.
5. Mount unit securely to wall by putting at least three screws
through mounting holes
E
1
-
3
.
Screws and plastic wall anchors for mounting on masonry or
wood are provided.
5. Water connections
!
NOTICE: EXCESSIVE HEAT FROM SOLDERING ON COPPER
PIPES NEAR THE TEMPRA MAY CAUSE DAMAGE.
THE COLD WATER CONNECTION TO THE UNIT MUST BE
DISCONNECTED PERIODICALLY IN ORDER TO CLEAN
THE FILTER SCREEN. IT IS REQUIRED TO USE WATER
CONNECTIONS THAT ARE EASILY DETACHABLE SUCH AS
BRAIDED STEEL FLEX CONNECTORS.
!
NOTICE: HARD WATER OR WATER WITH A HIGH MINERAL
COUNT MAY DAMAGE THE UNIT. DAMAGE TO THE UNIT
CAUSED BY SCALE OR A HIGH MINERAL COUNT IS NOT
COVERED UNDER THE WARRANTY.
1. All plumbing work must comply with national and applicable
state and local plumbing codes.
2. A pressure reducing valve must be installed if the cold water
supply pressure exceeds 150 PSI (10 bar).
3. Make certain that the cold water supply line has been flushed
to remove any scale and dirt.
4.
D
Also, the TEMPRA unit has a built in filter screen
1
that
should be cleaned from time to time. Clean screen and put the
screen and the washer
2
back into their original position.
5. The cold water connection (inlet) is on the right side of the
unit, and the hot water connection (outlet) is on the left side
of the unit.
6.
!
NOTICE: TANKLESS WATER HEATERS SUCH AS THE
TEMPRA ARE NOT REQUIRED TO BE EQUIPPED WITH
A PRESSURE AND TEMPERATURE RELIEF VALVE
(P&T). IF THE LOCAL INSPECTOR WILL NOT PASS
THE INSTALLATION WITHOUT A P&T, IT SHOULD BE
INSTALLED ON THE HOT WATER OUTLET SIDE OF THE
UNIT.
7. The TEMPRA on the hot side is designed for connection to copper
tubing, PEX tubing or a braided stainless steel hose with a
3/4" NPT female tapered thread.
The plumbing on the cold water inlet side needs to be such that
it can easily be removed to allow access to the inlet filter screen.
The easiest way to achieve this is to us a stainless steel
braided hose connector.
If soldering near the unit is necessary, please direct the flame
away from the housing of the unit in order to avoid damage.
8. When all plumbing work is completed, check for leaks and take
corrective action before proceeding.
6. Electrical connection
!
WARNING: BEFORE BEGINNING ANY WORK ON THE
ELECTRIC INSTALLATION, BE SURE THAT MAIN BREAKER
PANEL SWITCHES ARE "OFF" TO AVOID ANY DANGER OF
ELECTRIC SHOCK. ALL MOUNTING AND PLUMBING MUST
BE COMPLETED BEFORE PROCEEDING WITH ELECTRICAL
HOOK-UP. WHERE REQUIRED BY LOCAL, STATE OR
NATIONAL ELECTRICAL CODES THE CIRCUITS SHOULD
BE EQUIPPED WITH A "GROUND FAULT INTERRUPTER".
THE UNIT MUST BE PROPERLY GROUNDED IN ACCORDANCE
WITH STATE AND LOCAL CODES, OR IN ABSENCE OF SUCH
CODES, IN ACCORDANCE WITH NATIONAL ELECTRIC
CODE OR THE CANADIAN ELECTRIC CODE. FAILURE TO
ELECTRICALLY GROUND THE PRODUCT COULD RESULT IN
SERIOUS PERSONAL INJURY OR DEATH.
1. All electrical work must comply with national and applicable state
and local electrical codes.
2.
H
The TEMPRA should be connected to properly grounded
dedicated branch circuits of proper voltage rating. Ground must
be brought to the "Ground" at the circuit breaker panel.
TEMPRA 12 B/Plus: These units can be connected to a single circuit.
Use a supply cable protected by a double pole breaker (see
2
).
The TEMPRAS 15 to 36 must have multiple power sources.
TEMPRA 15, 20 or 24 B/Plus: These units require two independant
circuits. Use two supply cables protected by two separate double
pole breakers (see
2
).
TEMPRA 29 or 36 B/Plus These units require three independant circuits.
Use three supply cables protected by three separate double pole
breakers (see
2
).
Please refer to the technical data table for the correct wire and circuit
breaker size. In all cases, make sure that the unit is properly grounded.
3. Cut the electrical connection cable to length and strip.
15 (380)
26_02_02_0893
4. The wire must be fed through the knock-outs located between the
hot and cold water connections
A
,
H
1
. The "live" wires must
be connected to the slots on the terminal block marked L1 and L2.
The ground wire must be connected to slot marked with the ground
symbol (see
I
) .
Loading ...