43
Honeywell 35 Series IP Cameras User Guide
2. Check the Enable checkbox to enable people countering.
3. Configure the detection area.
Press and hold the left mouse button, and drag in the video area to draw a
detection area
Click CLEAR to delete a detection area.
4. Check the OSD enable checkbox to enable OSD display of people countering.
5. Configure the Countering clear interval, Area type and Alarm threshold.
a Select interval time to configure the Countering clear interval, the camera will
clear counting numbers within every setting time interval. Click CLEAR
COUNTING to clear current counting number.
b Check the enable checkbox of Set correction value to enable counting
correction which already stay on the In area. Input people number which is
already stay in the In area.
c Check the enable checkbox of Over people number alarm to enable alarm
function when stay people number over the number setting in Alarm
threshold box.
6. Select the Output channel.
7. Check the check boxes to enable Alarm record and SMTP.
8. Click SAVE.