LEAK TESTING LOW FLAME ADJUSTMENT
The valves on the side burner feature an adjustable low setting. Due to fluctuations in gas
pressure, or heating value you may feel it necessary to increase or decrease gas flow in the
low position. If the gas type has been converted from natural to LP or vice-versa, the low
flame setting must be reviewed and adjusted.
1
3
4
2
Remove the dial.
While holding the valve shaft with pliers,
insert a flat-tipped screwdriver into the
shaft and, while viewing the burner, adjust
to a minimum stable flame.
Push in and hold the selected dial
for 2 seconds before turning to HI.
Hold for 10 seconds to light the
selected burner.
Turn the control dial counter-
clockwise to the lowest setting.
BEZEL FRONT VIEW
1
2
Prepare soap solution by combining
one part liquid detergent and one
part water. Pour into a spray bottle.
Ensure all control valves are in the
OFF position before turning the gas
supply ON.
Check all connections from the
supply line or LP cylinder by
applying the solution around the
connection, tubing and end of the
manifold. Soap bubbles will appear
where a leak is present.
A complete gas tightness check must be performed at the installation site. Periodically
check the whole system for leaks, or immediately if the smell of gas is present.
When using a LP gas cylinder ensure it is installed in a vertical position to provide the
required vapor withdrawal.
If a leak is present
Immediately turn the gas supply
OFF and tighten any leaking connections. Turn gas ON,
and recheck. If you cannot stop a gas leak turn the gas supply OFF and call your local gas
utility or the dealer you purchased the appliance from. Only parts recommended by the
manufacturer should be used on the unit, substitution can void the warranty.