En-3
1-5. INSTALLATION DIAGRAM
Units should be installed by licensed contractor according to
local code requirements.
Afterthe leak test, apply insulat-
ing material tightly so that there
is no gap.
When the piping is to be attached to
a wall containing metals (tin plated)
or metal netting, use a chemically
treated wooden piece 25/32 in. (20
mm)or thicker between the wall
and the piping or wrap 7 to 8 turns
of insulation vinyl tape around
the piping.
To use existing piping, perform
COOL operation for 30 minutes
and pump down before removing
theoldairconditioner.Remakeare
according to the dimension for new
refrigerant.
PARTS TO BE PROVIDED AT YOUR SITE
(A) Power supply cord* 1
(B) Indoor/outdoor unit connecting wire* 1
(C) Extension pipe 1
(D) Wallholecover 1
(E) Piping tape 1
(F)
Extensiondrainhose(orsoftPVC
hose, 19/32 in. (15 mm) inner
diameterorhardPVCpipeVP16)
1
(G) Refrigeration oil
Little
amount
(H) Putty 1
(I) Pipexingband 2 to 7
(J) Fixing screw for (I) 2 to 7
(K) Wallholesleeve 1
* Note:
Place indoor/outdoorunit connecting wire (B) and
power supply cord (A) at least 3 ft. (1 m) away from
theTVantennawire.
The“Q’ty”for(B)to(K)intheabovetableisquantity
to be used per indoor unit.
More than
3-15/16 in.
(100 mm)
Open as a rule
More than 19-11/16
in. (500 mm) if the
front and both sides
are open
More than 3-15/16 in. (100 mm)
More than 7-7/8 in. (200 mm)
if there are obstacles to both
sides
Open as a rule
More than 19-11/16 in. (500 mm) if the
back,bothsidesandtopareopen
More than 13-25/32 in.
(350 mm)
Outdoor unit installation
Air inlet
Air outlet
2-U-shape notched holes
(BaseboltM10)
Unit : inch
2-1. INSTALLING THE UNIT
Fix here with
M10 bolts.
Makethesetting
depth deeper.
Makewithwider.
Anchor leg
31/32 (25) or less
Anchor bolt length
Anchor bolt pitch
(Unit: inch (mm))
• Besuretoxtheunit’slegswithboltswheninstallingit.
• Besuretoinstalltheunitrmlytoensurethatitdoesnotfallbyanearthquakeoragust.
• Refertothegureintherightforconcretefoundation.
• IncaseofMXZ-2C20NAHZ2,MXZ-3C24/30NAHZ2,donotusethedrainsocketandthedraincaps.
• IncaseofMXZ-5C42NA2,donotusethedrainsocketandthedraincapsinthecoldregion.Drainmayfreezeanditmakesthefanstop.
23-5/8
(600)
14-9/16
(370)
Outdoor unit installation
37-13/32
23-5/8
6-7/8
2 - (15/32 × 1-31/32)
ovalholes(BaseboltM10)
Air inlet
13
14-9/16
16-13/32
Air inlet
Air outlet
2-U-shape notched holes
(BaseboltM10)
Unit : mm
950
600175
2 - 12 × 36
ovalholes(BaseboltM10)
Air inlet
330
370
417
2. OUTDOOR UNIT INSTALLATION