RAID 00 Drive Groups
A RAID 00 drive group is a spanned drive group that creates a striped set from a series of
RAID0 drive groups. A RAID00 drive group does not provide any data redundancy, but, along
with the RAID0 drive group, does o󰀨er the best performance of any RAID level. A RAID00 drive
group breaks up data into smaller segments and then stripes the data segments across each
drive in the drive groups. The size of each data segment is determined by the stripe size. A
RAID00 drive group o󰀨ers high bandwidth.
Uses Provides high data throughput, especially for large les.Any environment that does not
require fault tolerance.
Strong points Provides increased data throughput for large les.
No capacity loss penalty for parity.
Weak points Does not provide fault tolerance or high bandwidth.
All data lost if any drive fails.
Drives 2 through 256
NOTE
RAID level 00 is not fault tolerant. If a drive in a RAID 0 drive group fails, the entire virtual drive (all drives
associated with the virtual drive) fails.
By breaking up a large le into smaller segments, the controller can use both SAS drives and
SATA drives to read or write the le faster. A RAID00 drive group involves no parity calculations
to complicate the write operation. This situation makes the RAID00 drive group ideal for
applications that require high bandwidth but do not require fault tolerance. The following table