MODELS MUA006A • MUA008A • MUA010A
Page 5
INSTALL THE DAMPER
OUTSIDE AIR
TO CENTRAL SYSTEM
RETURN AIR OR INTERIOR
WALL REGISTER
DAMPER FLAP (Install in
vertical position shown.)
AIR FLOW AIR FLOW
SET SCREW
Installthedamperasshown.Makesuredamperflapisinaverti-
cal position when closed and power is off. The set screw can be
used to adjust the damper opening - thereby balancing the inside
and outside air pressure when the range hood exhausts at high
speed.
PRESSURE SWITCH
OPERATION
The pressure switch is designed to operate when the static
pressureincreasesto0.05”Psormore.Itmaynotoperateatlow
speeds since the pressure is below this limit.
MULTIPLE DAMPERS
Morethanonedampermayberequiredtobalancethesystem.
If more than oneis requireduse (1)MUA006A,MUA008A,or
MUA010A and then use the 54060012 (6”), 54060013 (8”), or
54060014(10”)dampersasadditionaldampers.
INSTALLATION OF
PRESSURE SWITCH AND
PROBE
For the probe & pressure switch to work effectively the roof or
wall cap must have a spring loaded damper.