Specifications
Resettingtheproducttofactorydefaultsettings.SeeResettofactorydefaultsettingsonpage29.
Connectors
Networkconnector
RJ45EthernetconnectorwithPoweroverEthernetPlus(PoE+).
UL:PoweroverEthernet(PoE)shallbesuppliedbyaUL294listedPoweroverEthernetIEEE802.3af/802.3atType1Class3orPower
overEthernetPlus(PoE+)IEEE802.3atType2Class4powerlimitedinjectorthatprovides44–57VDC,15.4W/30W.Powerover
Ethernet(PoE)hasbeenevaluatedbyULwithAXIST8133Midspan30W1-port.
Readerconnector
One8-pinterminalblocksupportingbothOSDPandWiegandprotocolsforcommunicationwiththereader.
ItcanconnectuptotwoOSDPreaders(multi-drop)oroneWiegandreader.500mAat12VDCisreservedforallreadersconnected
tothedoorcontroller.
ConguredforoneOSDPreader
FunctionPinNote
Specications
DCground(GND)
1
0VDC
DCoutput(+12V)
2
Suppliespowertoreader.12VDC,max500mA
A
3
Halfduplex
B
4
Halfduplex
ConguredfortwoOSDPreaders(multi-drop)
FunctionPinNote
Specications
DCground(GND)
1
0VDC
DCoutput(+12V)
2
Suppliespowertoboth
readers.
12VDC,max
500mAcombinedforboth
readers
A
3
Halfduplex
B
4
Halfduplex
Important
Whenthereaderispoweredbythecontroller,thequaliedcablelengthisupto200m(656ft).VeriedonlyforAxisreaders.
Whenthereaderisnotpoweredbythecontroller,thequaliedcablelengthforreaderdataisupto1000m(3280,8ft)ifthe
followingcablerequirementsaremet:1twistedpairwithshield,AWG24,120ohmimpedance.VeriedonlyforAxisreaders.
ConguredforoneWiegandreader
FunctionPinNote
Specications
DCground(GND)
1
0VDC
24