REMOVAL
Outdoor Unit
4.Remove front panel
5.Remove right side plate
Procedure
6.Remove axial flow blade
Steps
Remove connection screws connecting the
front panel with the chassis and the motor
support, and then remove the front panel.
front panel
right side plate
Remove connection screws connecting the
right side plate with the valve support and
the electric box. Then remove the right side
plate.