2N 916115 Access Unit M Bluetooth and RFID

2N Access Unit M User Manual - Page 42

For 916115.

PDF File Manual, 56 pages, Read Online | Download pdf file

916115 photo
Loading ...
Loading ...
Loading ...
2N TELEKOMUNIKACE a.s., www.2n.cz 42/56
Factory Reset
Follow the instructions below to :reset the factory default values
Press and hold the RESET button.
Wait until the red and green LEDs go on simultaneously and the acoustic signal
(approx. 15–35 s). can be heard
Wait until the red LED goes off and the can be heard acoustic signal
(approx. for another 3 s).
Wait until the green LED goes off and the red LED goes on again and acoustic
can be heard (approx. for another 3 s). signal
Wait until the red LED goes off and the can be heard acoustic signal
(approx. for another 3 s).
Release the RESET button.
Caution
In case the factory default values are reset on the device with a firmware
version 2.18 or higher, it is necessary to reprogram using Security Relay
the instructions from Subsection 2.4 Extending ModuleConnection
Loading ...
Loading ...