Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/3252117-ds-2de4415iw-des5/bg15.png)
4.
Input Mounng Height of the device.
5.
Input or draw the min. pupil distance and the max. pupil distance.
The Min. Pupil Distance and the Max. Pupil Distance are used to improve detecon accuracy.
Only targets whose pupil distance are between the maximum distance and the minimum
distance trigger the capture.
Click and to draw the distance on live image, or input values in the text elds of Min. Pupil
Distance and Max. Pupil Distance.
6.
Click Save.
7.
Set arming schedule. See Set Arming Schedule .
8.
Set linkage method. See Linkage Method Sengs .
3.1.2 Expert Mode Sengs
Steps
1.
Oponal: Click Lock to lock PTZ control to prevent the interrupon from other PTZ related acon
during conguraon.
Normally, the PTZ control is automacally locked when you enter the conguraon interface.
You can manually resume the lock when the countdown is over.
2.
Input Mounng Height of the device.
3.
Set detecon scenes and detecon areas.
1) Select a detecon scene.
2) Adjust the live image to a desired scene. You can use PTZ control buons or click to locate a
scene with a face.
3) Click
, and draw a detecon area on live image.
4) Input or draw the min. pupil distance and the max. pupil distance.
The Min. Pupil Distance and the Max. Pupil Distance are used to improve detecon accuracy.
Only targets whose pupil distance are between the maximum distance and the minimum
distance trigger the capture.
Click and to draw the distance on live image, or input values in the text elds of Min.
Pupil Distance and Max. Pupil Distance.
5) Click Save.
6) Repeat above steps to set other detecon scenes and areas.
4.
Set patrol schedule.
1) Click Patrol Schedule.
2) Draw me bars as desired.
3) Click a me bar and click Conguraon.
4) Edit patrol path and input dwell me for each detecon scene.
Network Speed Dome User Manual
9
Loading ...
Loading ...