FLUKE FEV100/TY1 FEV100 Electric Vehicle Charging Station Adapter with type 1 connector and cable

User Manual for the Fluke FEV100 Electric Vehicle Charging Station Adapter with type 1 connector and cable - Page 12

For FEV100/TY1.

PDF File Manual, 14 pages, Read Online | Download pdf file

FEV100/TY1 photo
Loading ...
Loading ...
Loading ...
11
Specications
General Features
Input voltage ................................. U
L1/N
= 120 V, U
L2/N
= 120 V, U
L1/L2
= 208 V,
60 Hz (three-phase system) or
U
L1/N
= 120 V, U
L2/N
= 120 V, U
L1/L2
= 240
V, 60 Hz (single-phase system), ±10%
voltage uctuations from nominal
EV connector (EVC-13) ................ SAE J1772 socket, 16 A (type 1, 5P
single-phase)
Internal power consumption .........2 W max.
Operating temperature .................-4 °F to 104 °F (-20 °C to 40 °C)
Storage temperature ....................-4 °F to 122 °F (-20 °C to 50 °C)
Operating humidity range ............. 10 % to 85 % relative humidity
non-condensing
Storage relative humidity ..............0 % to 85 % non-condensing
Operating altitude .........................6561 ft (2000 m) max.
Dimensions (H × W × D) .............. Approx. 8.66 x 4.33 x 1.77 in
(220 x 110 × 45 mm) without cable
assembly
Weight ...........................................Approx. 4.4 lb (2 kg)
Safety standards ........................... IEC 61010-1, Pollution Degree 2
IEC 61010-2-030
Measurement category .................CAT II 250 V
IP protection class ........................IP54
Electromagnetic Compatibility (EMC)
International ................................. IEC 61326-1:
Basic Electromagnetic Environment;
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses
conductively-coupled radio frequency energy that is necessary for the
internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than
domestic and those directly connected to a low-voltage power supply
network that supplies buildings used for domestic purposes. There
may be potential diculties in ensuring electromagnetic compatibility in
other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential
environments and may not provide adequate protection to radio
reception in such environments.
USA (FCC) 47 ............................... 47 CFR 15 subpart B. This product is
considered an exempt device per clause
15.103.
Functions
CP states ......................................A, B, C, D
CP Error “E” ..................................On/o󰀨
PE Error ........................................On/o󰀨
GFCI test ...................................... Yes, test resistor of 2 kΩ connected
between L1 and PE, time limitation 40 ms
PE Pre-Test (typical) .....................Visible indication >30 V on PE conductor
Outputs (for test purpose only)
Measuring terminals
L1, L2/N, PE .................................Max. 250 V 50/60 Hz, CAT II 250 V
CP signal output terminals ........... Approx. ±12 V (under normal conditions),
in case of wrong wiring or error of the
charging station these terminals can be
hazardous ≥ max. 250 V against PE
1.888.610.7664 sales@GlobalTestSupply.com
Fluke-Direct.com
Loading ...
Loading ...