Asko HID352GC 38cm 2 Zone Induction Cooktop

User Manual - Page 54

For HID352GC.

PDF File Manual, 64 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
Number and cross section
of Power cord wires
Power cord
type
Connection typeCurrent limiter
settings
3x1,5 mm²H05V2V2-F1 phase, 1 neutral conductor1x16A
3x1,5 mm²H05V2V2-F1 phase, 1 neutral conductor1x13A
3x1,5 mm²H05V2V2-F1 phase, 1 neutral conductor1x10A
3x1,5 mm²H05V2V2-F1 phase, 1 neutral conductor1x06A
Voltage between line and neutral conductor must be 220240 V~.
1 phase, 1 neutral conductor (220240 V~, 50-60 Hz)
L = black/brown
N = blue
= yellow-green
For appliance types: BI1CA, BI6CA, BI6CB, BI7CA, BI8CA, BI8CB, BI9CE
NOTE!
Note: The appliance type can be found on the rating plate on the bottom of the appliance.
Voltage between line and neutral conductor must be 220240 V~. Voltage between lines must be
380415 V~. Power cord core cross sectional area should be at least as listed in Table for the
following current limiter settings which should be adjusted to your circuit breakers:
Number and cross section
of Power cord wires
Power cord
type
Connection typeCurrent limiter
settings
4x1,5 mm²H05VV-F2 phases, 1 neutral conductor2x16A
4x1,5 mm²H05VV-F2 phases, 1 neutral conductor2x13A
4x1,5 mm²H05VV-F2 phases, 1 neutral conductor2x10A
4x1,5 mm²H05VV-F2 phases, 1 neutral conductor2x06A
5x1,5 mm²H05VV-F2 phases, 2 neutral conductors
(only for NL)
2x16A
3x4,0 mm²H05VV-F1 phase, 1 neutral conductor1x32A
3x4,0 mm²H05VV-F1 phase, 1 neutral conductor1x25A
3x4,0 mm²H05VV-F1 phase, 1 neutral conductor1x20A
3x4,0 mm²H05VV-F1 phase, 1 neutral conductor1x16A
3x4,0 mm²H05VV-F1 phase, 1 neutral conductor1x13A
3x4,0 mm²H05VV-F1 phase, 1 neutral conductor1x10A
3x4,0 mm²H05VV-F1 phase, 1 neutral conductor1x06A
54
Electrical installation