Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/15491261-ip9165-lpc-v2/bg100.png)
VIVOTEK
256 - User's Manual
© 2019 VIVOTEK INC. All Right Reserved
121
NAME VALUE SECURITY
(get/set)
DESCRIPTION
7: LOG_DEBUG
setparamlevel 0~2 6/6 Show log of parameter setting.
0: disable
1: Show log of parameter setting set
from external.
2. Show log of parameter setting set
from external and internal.
7.23 SNMP
Group: snmp (capability_protocol_snmp > 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
v2 <boolean> 6/6 SNMP v2 enabled. 0 for disable, 1 for
enable
v3 <boolean> 6/6 SNMP v3 enabled. 0 for disable, 1 for
enable
secnamerw string[31] 6/6 Read/write security name
secnamero string[31] 6/6 Read only security name
authpwrw string[8~128] 7/6 Read/write authentication password
authpwro string[8~128] 7/6 Read only authentication password
authtyperw MD5,SHA 6/6 Read/write authentication type
authtypero MD5,SHA 6/6 Read only authentication type
encryptpwrw string[8~128] 7/6 Read/write passwrd
encryptpwro string[8~128] 7/6 Read only password
encrypttyperw DES 6/6 Read/write encryption type
encrypttypero DES 6/6 Read only encryption type
rwcommunity string[31] 6/6 Read/write community
rocommunity string[31] 6/6 Read only community
syslocation string[128] 6/6 System location
syscontact string[128] 6/6 System contact
Loading ...
Loading ...