Hikvision DS-2TD95C8-300ZK2FL/W Thermal & Optical Bi-spectrum Network Sphere Positioning System

User Manual - Page 47

For DS-2TD95C8-300ZK2FL/W.

PDF File Manual, 128 pages, Read Online | Download pdf file

DS-2TD95C8-300ZK2FL/W photo
Loading ...
Loading ...
Loading ...
Thermal & Optical Bi-spectrum PTZ Network Camera User Manual
32
Note
You can draw the max. size and min. size rectangles according to the real target in the scene.
The recommended size is 1.2 times of the target.
The height of the rectangle is a more important factor as it is the main difference to tell apart
a human and an animal.
Click to copy the same settings to other rules.
7. Click Save.
8. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for
setting linkage method.
6.3.3 Set the Scene Auto-Switch
The device support patrol tracking for multiple important scenes. The alarm will be triggered if the
rule is broken during patrol sequence.
Before You Start
Finish scene settings in advance. See Set Detection Scenes and Tracking for configuration
instructions.
Steps
1. Go to VCA Scene Auto-Swtich to configure this function.
2. Set the scene patrol sequence.
Scene Name
Select a scene name from the drop down list.
Duration
Set the dwell time of the scene when doing patrol tracking.
3. Click the up, down arrow to adjust the patrol sequence.
4. Click Save.
6.3.4 Set Polling Plan
Both the optical channel and the thermal channels support the perimeter protection. Set the
working shift for each channel.
Before You Start
The detection scenes and rules should be configured in advance for both channels.
Steps
1. Go to Configuration VCA Camera 01/Camera 02 Basic Settings Polling Plan.
2. Select a polling mode.
Auto
The device automatically activates the optical channel for perimeter
Loading ...
Loading ...
Loading ...