AcuRite 01094M Temperature & Humidity Station with 3 Indoor/Outdoor Sensors

Product's Documents

Below are documents related to this product, you can read online or download:
01094M photo

User Manual

This is the main product document for model 01094M.

The file format is pdf, 14 pages, you can download this manual here .

background
'loll SENSORB
'loll
,□
Of
' .,
6 ,Of
, ..
Y3~
.%.
s 1%
TOOJ.YS
'-
lJWIS
'loll SENSORC DISPLAY
y9:
,2°f
' .,
Gr
.%.
53~
T00AY'S
OI(
LOWS
WED 12:35pm
10/25
ACU>RITE
Instruction Manual
Home Environment Display
model 06043
This product requires at least one AcuRite Sensor
(sold separately) to be operational.
CONTENTS
Unpacking Instructions ........... 2
Package Contents .................. 2
Product Registration ............... 2
Features & Benets................. 3
Setup .................................... 4
Set the Time, Date & Units ...... 5
Placement Guidelines ............. 6
Using the Display................... 6
Programmable Alarms............ 7
Troubleshooting ..................... 8
Care & Maintenance.............. 9
Calibration ............................ 9
Specications......................... 9
FCC Information .................... 9
Customer Support .................10
Warranty..............................10
Questions? Contact Customer Support at
(877) 221-1252 or visit www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
background
Archived Products
Congratulations on your new AcuRite product. To ensure the best possible
product performance, please read this manual in its entirety and retain it for
future reference.
Unpacking Instructions
Remove the protective lm that is applied to the LCD screen prior to using this
product. Locate the tab and peel off to remove.
Package Contents
1. Display with Tabletop Stand
2. Instruction Manual
IMPORTANT
PRODUCT MUST BE REGISTERED
TO RECEIVE WARRANTY SERVICE
PRODUCT REGISTRATION
Register online
to receive 1 year
warranty protection
www.AcuRite.com
Register a Product
2
background
6tj
cb
w
EN. 'f.lA
~n1
...
-
"'°'"
..
-
,u~
....
T
.J
...
-
-
-
Ll3:
5 ,~
'-
-
-
-
w N' RC DISPLAY
-
y9:
,20f
'
~
-
-
63~
L
,. 53:
~5
-
~"'
-
IJED
T
10/i.'5
-
-
ACU•RITE
Features & Benets
12 11 10 9 14 13
15
1
2
16
17
3
18
4 5 6 7 8 19
DISPLAY FRONT
1. Sensor Signal Strength
Signal strength detected for the indicated
external sensor (sold separately).
2. Current Temperature
Reported by indicated sensor. Arrow icon
indicates the direction the temperature
is trending.
3. Record Indicators
Indicates today’s high or low records are
being viewed.
4. Day of the Week
5. Clock
6. Humidity Level Indicator
Indicates a high, low or ideal humidity
level in the location of the display.
7. Date
8. Current Humidity
Reported by indicated sensor. Arrow
icon indicates the direction the humidity
is trending.
9. Low Battery Indicator
For the sensor that is reporting data for
the corresponding location.
10. Sensor Indicator
Identifes sensors by A-B-C channel
settings (see page 4).
11. RECORDS Button
Press to view today’s high and low records.
12. Alarm ON Indicator
Indicates alarm is activated to emit an
audible alert when conditions exceed
your presets (see page 7).
DISPLAY BACK
13. Integrated Hang Hole
For easy wall mounting.
14. SET Button
For setup preferences.
15.
and Buttons
For setup preferences.
16. Button
For alarm setup.
17. RESET Button
Full reset to factory defaults.
18. Battery Compartment
19. Foldout Tabletop Stand
20. Battery Compartment Cover
(not shown)
3
background
1,----
~~.:-------------=~-I
-~
= IDS CT S~~'h
- A•B<: re= =
- INDOOR °C/"F
= USEONLY =
~=
. -.
-
-
.;
-
-
-
-
-
-
SETUP
Display Setup
1
Install Sensor Batteries & Set A-B-C Channel
BEFORE powering on the display, install batteries for all wireless sensors
(sold separately) that you would like to synchronize with the display.
NOTE: If pairing more than one wireless sensor with the display, the A-B-C
channel must differ between each sensor. Verify that each sensor has a different
channel selected by following the instructions in the corresponding sensor manual.
2
Install or Replace Display Batteries
Install Sensor Batteries
& Set A-B-C Channel
1
A-B-C
Channel
A-B-C
Channel
1. Remove the battery compartment cover.
2. Insert 3 x AA alkaline batteries into the battery compartment, as shown.
Follow the polarity (+/-) diagram in the battery compartment.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE
WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be
used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used
3. Replace the battery cover.
Install Batteries
3 AA Batteries
2
batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fre,
as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge
non-rechargeable batteries. DO NOT short-circuit the supply terminals.
4
background
Set the Time, Date & Units
Press and release the “SET” button, located on the back of the display, to enter
SET MODE. Once in set mode, the preference you are currently setting will
blink on the display.
To adjust the currently selected (ashing) item, press and release the “ or
buttons (press and HOLD to fast adjust).
To save your adjustments, press and release the “SET” button again to adjust
the next preference. The preference set order is as follows:
AUTO DST (Daylight Saving Time ON or OFF)*
CLOCK HOUR
CLOCK MINUTE
CALENDAR MONTH
CALENDAR DATE
CALENDAR YEAR
TEMPERATURE UNITS (ºF or ºC)
*If you live in an area that observes DST, DST should be set to ON, even if it is
not currently Daylight Saving Time.
You will automatically exit SET MODE if no buttons are pressed for 10 seconds.
Enter SET MODE at any time by pressing the “SET” button.
Expand the System
The display features built-in sensors for measuring temperature at its location.
The display can be expanded to track additional areas by using compatible
Temperature & Humidity Sensors (optional; sold separately). Add up to 3
indoor/outdoor sensors to observe conditions in additional locations within
330 ft (100 m).
Compatible Sensors are available at: www.AcuRite.com
Compatible Sensors Features:
Temperature & Humidity Sensor
Model 06002
• Measures temperature and humidity
• Weather-resistant for indoor and
outdoor applications
Temperature & Humidity Sensor
Model 06044
• Integrated digital display for conditions
at a glance
• Measures temperature and humidity
• For indoor applications
5
background
10' GT
sJ Sf
~B le?
B ·IJ
Placement for Maximum Accuracy
AcuRite products are sensitive to surrounding environmental conditions. Proper
placement is critical to the accuracy and performance of this product.
Display Placement
Place the display in a dry area free of dirt and dust. Display
stands upright for tabletop use and is wall-mountable.
Important Placement Guidelines
To ensure accurate temperature measurement, place product out of direct
sunlight and away from any heat sources or vents.
Display and add-on sensors must be within 330 ft (100 m) of each other.
To maximize wireless range, place product away from large metallic items,
thick walls, metal surfaces, or other objects that may limit wireless
communication.
To prevent wireless interference, place product at least 3 ft (.9 m) away from
electronic devices (TV, computer, microwave, radio, etc.).
OPERATION
Using the Home Environment Display
High & Low Records
Today’s high and low records are displayed for display and sensor
temperature and humidity. Today’s records automatically clear at 12:00am
midnight every day.
Press the “RECORDS” button to view today’s HIGH recorded values for
temperature and humidity. Press again to view today’s LOW recorded values.
You will automatically exit the record view if no buttons are pressed for 5
seconds.
To manually clear HIGH or LOW records, press and HOLD both the “ and
“ buttons simultaneously for 3 seconds while viewing the records you wish
to clear. Dashes display to conrm you have cleared the records.
6
background
T
T
•·n·•
•·n·•
(((-41)))
...
T
~
•·D·•
Programmable Alarms
This display features programmable alarms that sound an alert to notify you
when a value (for temperature or humidity) has been reached or exceeded.
When an alarm is triggered, the display emits an audible beep and ashes data
in the affected category. You can customize the alarms by turning ON or OFF
the alarms you’d like activated or deactivated, and by inputting your own values
to trigger the alarm.
Setup an Alarm
1. Press and release the “ ” button until the reading for which you wish to
set an alarm is shown on the display. “ ” will be shown.
2. Press and release the or buttons until “ appears.
3. Press and release the “SET” button. The current HIGH alarm value will be
shown.
4. Press and release the or buttons to adjust the alarm’s HIGH value.
5. Press and release the “SET” button. The current LOW alarm value will be
shown.
6. Press and release the or buttons to adjust the alarm’s LOW value.
7. Press and release the “SET” button to end alarm adjustments, OR press
and release the “ ” button to adjust the next alarm’s values.
Disable an Alarm
1. Press and release the “ ” button until the reading for which you wish to
disable an alarm is shown on the display. will be shown.
2. Press and release the or buttons until “ ” appears.
3. Press and release the “ ” button to cycle to the next reading.
4. Repeat steps 1-3, as needed.
Note: To disable ALL alarms at once, press and HOLD the button for
10 seconds.
You will automatically exit alarm SET MODE if no buttons are pressed for
10 seconds. Enter alarm SET MODE at any time by pressing the button.
7
background
Tull
Troubleshooting
Problem Possible Solution
No reception
no bars
If the wireless signal indicator shows no bars:
Relocate the display and/or wireless sensor. The
products must be within 330 ft (100 m) of each other.
Make sure products (display and Sensors) are placed
at least 3 feet (.9 m) away from electronics that may
interfere with the wireless communication (such as
TVs, microwaves, computers, etc).
Use standard alkaline batteries (or lithium batteries
in Sensors when temperature is below -4ºF/-20ºC).
Do not use heavy duty or rechargeable batteries.
Note: It may take a few minutes for the display and
sensor(s) to synchronized after batteries are replaced.
Display screen
not working
Check that the batteries are installed correctly.
Batteries may need to be replaced.
Sensor not recognized /
blank sensor data
If the Home Environment Display is being used with
more than one Temperature & Humidity Sensor (models
06002 or 06044), the A-B-C channels must differ
between each sensor.
1. Bring the display and wireless sensors together and
position them side-by-side.
2. Remove the batteries from the display.
3. Verify that each sensor has a different A-B-C
channel selected.
Model 06002 - Locate the A-B-C switch inside the
battery compartment to adjust channel setting.
Model 06044 - Locate the A-B-C button on the back
of the sensor to adjust channel setting (indicated on
sensor display).
4. Re-install sensor batteries (if applicable).
5. Re-install display batteries.
Note: It may take a few minutes for the display and
sensor(s) to synchronized after batteries are replaced.
Inaccurate
temperature
or humidity
Verify the product that is reporting an inaccurate
temperature reading is placed out of direct sunlight and
away from any heat sources or vents (see page 6).
• Verify the product that is reporting an inaccurate
humidity reading is positioned away from moisture
sources (see page 6).
If your AcuRite product does not operate properly after trying
the troubleshooting steps, visit www.AcuRite.com or call
(877) 221-1252 for assistance.
8
background
Care & Maintenance
Display Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep
away from dust, dirt and moisture. Clean ventilation ports regularly with a
gentle puff of air.
Calibration
The temperature and humidity readings can be calibrated on the display to
improve accuracy. Calibration can improve accuracy when product placement or
environmental factors impact your data accuracy.
1. To access calibration mode, press AND HOLD the “ “, “SET”, and “
buttons simultaneously for at least 5 seconds.
2. To adjust the currently selected item, press and release the “ “ or “
buttons to calibrate the data value higher or lower from the actual reading.
3. To save your adjustments, press and release the “SET” button to adjust the
next preference. The “ ” icon will remain illuminated next to calibrated values.
After 10 seconds of inactivity, the display will save the adjustments and exit
calibration mode.
Note: Calibrations will be erased if the display is reset or if the batteries are
removed.
Specications
DISPLAY’S BUILT-IN
TEMPERATURE SENSOR RANGE
32ºF to 122ºF; 0ºC to 50ºC
DISPLAY’S BUILT-IN
HUMIDITY SENSOR RANGE
1% to 99% RH
WIRELESS RANGE
330 ft / 100 m depending on home construction materials
OPERATING FREQUENCY
433 MHz
POWER
3 x AA alkaline batteries
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
1- This device may NOT cause harmful interference, and
2- This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modications to this unit not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modications to this equipment.
Such modications could void the user authority to operate the equipment.
9
background
Archived Products
Customer Support
AcuRite customer support is committed to providing you with best-in-
class service. For assistance, please have the model number of this
product available and contact us in any of the following ways:
(877) 221-1252
Visit us at www.AcuRite.com
Installation Videos Register your Product
Instruction Manuals Support User Forum
Replacement Parts Submit Feedback & Ideas
IMPORTANT
PRODUCT MUST BE REGISTERED
TO RECEIVE WARRANTY SERVICE
PRODUCT REGISTRATION
Register online
to receive 1 year
warranty protection
www.AcuRite.com
Register a Product
Limited 1 Year Warranty
AcuRite is a wholly owned subsidiary of Chaney
Instrument Company. For purchases of AcuRite
products, AcuRite provides the benets and services set
forth herein. For purchases of Chaney products, Chaney
provides the benets and services set forth herein.
We warrant that all products we manufacture under this
warranty are of good material and workmanship and, when
properly installed and operated, will be free of defects for a
period of one year from the date of purchase.
Any product which, under normal use and service, is proven
to breach the warranty contained herein within ONE YEAR
from date of sale will, upon examination by us, and at our sole
option, be repaired or replaced by us. Transportation costs and
charges for returned goods shall be paid for by the purchaser.
We hereby disclaim all responsibility for such transportation
costs and charges. This warranty will not be breached, and we
will give no credit for products which have received normal
wear and tear not affecting the functionality of the product,
been damaged (including by acts of nature), tampered,
abused, improperly installed, or repaired or altered by others
than our authorized representatives.
Remedy for breach of this warranty is limited to repair or
replacement of the defective item(s). If we determine that repair
or replacement is not feasible, we may, at our option, refund
the amount of the original purchase price
THE ABOVE-DESCRIBED WARRANTY IS THE SOLE WARRANTY
FOR THE PRODUCTS AND IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED. ALL OTHER WARRANTIES
OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN
ARE HEREBY EXPRESSLY DISCLAIMED, INCLUDING WITHOUT
LIMITATION THE IMPLIED WARRANTY OF MERCHANTABILITY
AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE.
We expressly disclaim all liability for special, consequential,
or incidental damages, whether arising in tort or by contract
from any breach of this warranty. Some states do not allow the
exclusion or limitation of incidental or consequential damages,
so the above limitation or exclusion may not apply to you.
We further disclaim liability from personal injury relating to
its products to the extent permitted by law. By acceptance of
any of our products, the purchaser assumes all liability for the
consequences arising from their use or misuse. No person, rm
or corporation is authorized to bind us to any other obligation
or liability in connection with the sale of our products.
Furthermore, no person, rm or corporation is authorized
to modify or waive the terms of this warranty unless done in
writing and signed by a duly authorized agent of ours.
In no case shall our liability for any claim relating to our
products, your purchase or your use thereof, exceed the
original purchase price paid for the product.
Applicability of Policy
This Return, Refund, and Warranty Policy applies only to
purchases made in the United States and Canada. For
purchases made in a country other than the United States or
Canada, please consult the policies applicable to the country in
which you made your purchase.
Additionally, this Policy applies only to the original purchaser
of our products. We do cannot and do not offer any return,
refund, or warranty services if you buy products used or from
resale sites such as eBay or Craigslist.
Governing Law
This Return, Refund, and Warranty Policy is governed by the
laws of the United States and the State of Wisconsin. Any
dispute relating to this Policy shall be brought exclusively in the
federal or State courts having jurisdiction in Walworth County,
Wisconsin; and purchaser consents to jurisdiction within the
State of Wisconsin.
10
background
11
background
ACU
RITE®
ACU
RITE.
Weather Temperature Weather Kitchen
Clocks
Stations & Humidity Alert Radio Thermometers
& Timers
It’s more than accurate, it’s
AcuRite offers an extensive assortment of precision instruments,
designed to provide you with information you can depend on to
Plan your day with condence
.
www.AcuRite.com
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the
Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights
Printed in China
are the property of their respective owners. AcuRite uses patented technology.
06043 INST 030316 Visit www.AcuRite.com/patents for details.
background
Instruction Manual
Temperature & Humidity Sensor
model 06002 / 592TXR
Printed in China
06002M INST 082516
It’s More than Accurate, it’s
AcuRite offers an extensive assortment of precision instruments,
designed to provide you with information you can depend on to
Plan your day with confidence
.
www.AcuRite.com
Weather
Stations
Temperature
& Humidity
Weather
Alert Radio
Kitchen
Thermometers
& Timers
Clocks
Features & Benets
4
3
2
1
5
SENSOR
1. Integrated Hanger
For easy placement.
2. Wireless Signal Indicator
Flashes when data is being
wirelessly transmitted.
3. Battery Compartment
4. A-B-C Switch
5. Battery Compartment Cover
SETUP
Set the A-B-C Switch
The A-B-C switch is located inside
the battery compartment. It can be
set to A, B or C.
NOTE:
If being used with a
companion product that has an
A-B-C channel, you must select the
same letter choice for both the
sensor and the product it is being
paired with in order for the units to
synchronize.
Install or Replace Batteries
AcuRite recommends high quality
alkaline or lithium batteries in
the sensor for the best product
performance. Heavy duty or
rechargeable batteries are not
recommended.
Sensor Setup
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
1- This device may NOT cause harmful interference, and
2- This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modications to this unit not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equip
-
ment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modications to this equipment.
Such modications could void the user authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation of the device.
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the
Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights
are the property of their respective owners. AcuRite uses patented technology.
Visit www.AcuRite.com/patents for details.
1
2
The sensor requires lithium
batteries in low temperature
conditions. Cold temperatures
can cause alkaline batteries
to function improperly. Use
lithium batteries in the sensor for
temperatures below -4ºF / -20ºC.
1. Slide off the battery
compartment cover.
2. Insert 2 x AA batteries into
the battery compartment, as
shown. Follow the polarity
(+/-) diagram in the battery
compartment.
3. Replace the battery cover.
background
Specications
TEMPERATURE RANGE
-40°F to 158°F; -40°C to 70°C
HUMIDITY RANGE
1% – 99% RH (relative humidity)
BATTERY REQUIREMENTS
2 x AA alkaline or lithium batteries
WIRELESS RANGE
330ft / 100 m depending on home construction materials
OPERATING FREQUENCY
433MHz
32
A-B-C Switch
A B C
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper
placement of the sensor is critical to the accuracy and performance of this product.
Sensor Placement
The sensor is water-resistant and is designed for general indoor or
outdoor use, however, to extend its life place the sensor in an area
protected from direct weather elements.
Hang the sensor using the integrated hang hole or hanger, or by using
string (not included) to hang it from a suitable location, like a well covered
tree branch. The best location is 4 to 8 feet above the ground with
permanent shade and plenty of fresh air to circulate around the sensor.
Important Placement Guidelines
To ensure accurate temperature measurement, place sensor out of direct
sunlight and away from any heat sources.
Sensor must be within 330 ft (100 m) of companion unit (not included).
To maximize wireless range, place sensor away from large metallic items, thick
walls, metal surfaces, or other objects that may limit wireless communication.
To prevent wireless interference, place sensor at least 3 ft (0.9 m) away
from electronic devices (TV, computer, microwave, radio, etc.).
For more information, visit our Knowledge Base at http://www.AcuRite.com/kbase
Limited 1-Year Warranty
AcuRite is a wholly owned subsidiary of Chaney
Instrument Company. For purchases of AcuRite
products, AcuRite provides the benets and services set
forth herein. For purchases of Chaney products, Chaney
provides the benets and services set forth herein.
We warrant that all products we manufacture under this
warranty are of good material and workmanship and, when
properly installed and operated, will be free of defects for a
period of one year from the date of purchase.
Any product which, under normal use and service, is proven
to breach the warranty contained herein within ONE YEAR
from date of sale will, upon examination by us, and at our sole
option, be repaired or replaced by us. Transportation costs and
charges for returned goods shall be paid for by the purchaser.
We hereby disclaim all responsibility for such transportation
costs and charges. This warranty will not be breached, and we
will give no credit for products which have received normal
wear and tear not affecting the functionality of the product,
been damaged (including by acts of nature), tampered,
abused, improperly installed, or repaired or altered by others
than our authorized representatives.
Remedy for breach of this warranty is limited to repair or
replacement of the defective item(s). If we determine that repair
or replacement is not feasible, we may, at our option, refund
the amount of the original purchase price.
THE ABOVE-DESCRIBED WARRANTY IS THE SOLE WARRANTY
FOR THE PRODUCTS AND IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED. ALL OTHER WARRANTIES
OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN
ARE HEREBY EXPRESSLY DISCLAIMED, INCLUDING WITHOUT
LIMITATION THE IMPLIED WARRANTY OF MERCHANTABILITY
AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE.
We expressly disclaim all liability for special, consequential,
or incidental damages, whether arising in tort or by contract
from any breach of this warranty. Some states do not allow the
exclusion or limitation of incidental or consequential damages,
so the above limitation or exclusion may not apply to you.
We further disclaim liability from personal injury relating to
our products to the extent permitted by law. By acceptance of
any of our products, the purchaser assumes all liability for the
consequences arising from their use or misuse. No person, rm
or corporation is authorized to bind us to any other obligation
or liability in connection with the sale of our products.
Furthermore, no person, rm or corporation is authorized
to modify or waive the terms of this warranty unless done in
writing and signed by a duly authorized agent of ours.
In no case shall our liability for any claim relating to our
products, your purchase or your use thereof, exceed the
original purchase price paid for the product.
Applicability of Policy
This Return, Refund, and Warranty Policy applies only to
purchases made in the United States and Canada. For
purchases made in a country other than the United States or
Canada, please consult the policies applicable to the country in
which you made your purchase.
Additionally, this Policy applies only to the original purchaser
of our products. We cannot and do not offer any return,
refund, or warranty services if you buy products used or from
resale sites such as eBay or Craigslist.
Governing Law
This Return, Refund, and Warranty Policy is governed by the
laws of the United States and the State of Wisconsin. Any
dispute relating to this Policy shall be brought exclusively in the
federal or State courts having jurisdiction in Walworth County,
Wisconsin; and purchaser consents to jurisdiction within the
State of Wisconsin.
Customer Support
AcuRite customer support is committed to providing you with best-in-class service.
For assistance, please have the model number of this product available and contact
us in any of the following ways:
(877) 221-1252
PRODUCT REGISTRATION
Register online to receive 1 year warranty protection
www.AcuRite.com
IMPORTANT
PRODUCT MUST BE REGISTERED
TO RECEIVE WARRANTY SERVICE
Visit us at www.AcuRite.com
Installation Videos
Instruction Manuals
Replacement Parts
Register your Product
Support User Forum
Submit Feedback & Ideas
1
Install Batteries
2 AA batteries
2
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE
WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment that will not be
used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used
batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire,
as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge
non-rechargeable batteries. DO NOT short-circuit the supply terminals.

Specifications

AcuRite 01094M Questions and Answers

See other models: 02049 02043A1 01090M 00782A2 01125M