Vivotek MS8391-EV ~ EOL MS8391-EV 12MP Multiple Sensor Network Camera

User Manual - Page 203

For MS8391-EV ~ EOL.

PDF File Manual, 235 pages, Read Online | Download pdf file

MS8391-EV ~ EOL photo
Loading ...
Loading ...
Loading ...
VIVOTEK
User's Manual - 203
URL Command Document for All Series391
68
Inc. certificate information.
unit string[64] VIVOTEK
Inc.
6/6 Organizational unit name in the
certificate information.
commonname string[64] www.vivotek
.com
6/6 Common name in the certificate
information.
validdays 0 ~ 3650 3650 6/6 Valid period for the
certification.
7.31 Storage management setting
Currently its for local storage (SD card)
Group: disk_i<0~(n-1)> n is the total number of storage devices.
PARAMETER VA L UE Default SECURITY
(get/set)
DESCRIPTION
cyclic_enabled <boolean> 0 6/6 Enable cyclic storage method.
autocleanup_enabled <boolean> 0 6/6 Enable automatic clean up method.
Expired and not locked media files
will be deleted.
autocleanup_maxage 1~<positive
integer>
7 6/6 To specify the expired days for
automatic clean up.
7.32 Region of interest
Group: roi_c<0~(n-1)> for n channel product, and m is the number of streams which support ROI.
PARAMETER VA L UE Default SECURITY
(get/set)
DESCRIPTION
s<0~(m-1)>_home <coordinate> 0,0 1/6 ROI left-top corner coordinate.
s<0~(m-1)>_size <window size> 7552x1416 1/6
ROI width and height. The width
value must be
multiples of 16 and the
height value must be multiples of 8
Loading ...