Corbero CCIG9333 Placa Inducción

User Manual ESP - ENG - POR - Page 74

For CCIG9333.

PDF File Manual, 80 pages, Read Online | Download pdf file

CCIG9333 photo
Loading ...
Loading ...
Loading ...
21
3. The hotplate shall be installed such that better heat radiation can be ensured to
enhance its reliability.
4. The wall and induced heating zone above the table surface shall withstand heat.
5. To avoid any damage, the sandwich layer and adhesive must be resistant to heat.
6. A steam cleaner is not to be used.
9.7 Connecting the hob to the mains power supply
The power supply should be connected in compliance with the relevant standard, or a
single-pole circuit breaker. The method of connection is shown as the diagram.
This hob must be connected to the mains power supply only by a suitably qualified person.
Before connecting the hob to the mains power supply, check that:
l The domestic wiring system is suitable for the power drawn by the hob.
l The voltage corresponds to the value given in the rating plate
l The power supply cable sections can withstand the load specified on the rating plate.
To connect the hob to the mains power supply, do not use adapters, reducers, or branching
devices, as they can cause overheating and fire.
The power supply cable must not touch any hot parts and must be positioned so that its
temperature will not exceed 75˚C at any point.
Check with an electrician whether the domestic wiring system is suitable without alterations.
Any alterations must only be made by a qualified electrician.
If the cable is damaged or to be replaced, the operation must be carried out the by after-
sale agent with dedicated tools to avoid any accidents.
If the appliance is being connected directly to the mains an omnipolar circuit-breaker
must be installed with a minimum opening of 3mm between contacts.
The installer must ensure that the correct electrical connection has been made and that it
is compliant with safety regulations.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced by authorized technicians only.
The bottom surface and the power cord of the hob are not accessible after installation.
CCVG2902D
CCVG8322 / CCVG8422
CCIG2902D
CCIG9322 / CCIG9333
CCIG9422
H05RR-F3G1,5*
H05GG-F5G1,5*
H05RR-F2G1,5*
H07RN-F5G1,5*
H07RN-F4G1,5*
Loading ...
Loading ...
Loading ...