11.2016 / V2.0
INSTALLATION GUIDE
Isodrive 1600
www.schweigen.com.au
background
Page 2
Welcome
Thank you for purchasing your new Schweigen Isodrive system.
To get the maximum output from this unit, please read through this guide before use and installation.
This guide contains important information on the correct use and maintenance of the unit, as well as important
safety notes. This will ensure your personal safety and the lasting value of your Isodrive system.
Please always retain your proof of purchase to aid in any warranty queries.
This appliance and its packaging are produced by processes that minimise waste and respect
the environment.
Please help us to continue this eort to protect the environment by using the appliance eciently and dispose
of the packaging in a responsible manner.
background
Page 3
Index
1. Welcome _____________________________________________________________________________________ 2
2. Your Safety
Receiving your rangehood ______________________________________________________________________ 4
Before Installation ______________________________________________________________________________ 4
Electrical Cord __________________________________________________________________________________ 4
Motor Features ________________________________________________________________________________ 5
General Notes on Installation and Use ____________________________________________________________ 5
Recommended Installation Distance _____________________________________________________________ 5
Minimum Mounting Height ______________________________________________________________________ 6
Avoidance of Back Flow _________________________________________________________________________ 6
Safety of Children ______________________________________________________________________________ 6
Replacement of Supply Cord _____________________________________________________________________ 6
Why Flexi-duct _________________________________________________________________________________ 6
3. Description
Isodrive Motor _________________________________________________________________________________ 7
4. Installation
Roof Installation _______________________________________________________________________________ 8
Wall Installation ________________________________________________________________________________ 10
Installation Without Back Draught Shutter ______________________________________________ 10
Installation Through Wall with Back Draught Shutter ______________________________________ 12
Flat Roof Installation ___________________________________________________________________________ 13
Fan Unit Shutter Assembly __________________________________________________________ 14
Twin Motor Installation _____________________________________________________________ 15
Single Motor Installation Twin 200mm Outlet ____________________________________________ 17
5. Measurements
Measurements for Isodrive 1600 _____________________________________________________ 18
6. Flexible Duct
Flexible Ducting Installation _________________________________________________________ 19
Shallow Roof Space _______________________________________________________________ 20
Important Note __________________________________________________________________ 20
Securing Flexible Duct _____________________________________________________________ 21
7. Parts List
Parts List for Isodrive 1600 __________________________________________________________ 22
8. Maintenance
Roof Restoration or Cleaning ________________________________________________________ 24
9. Warranty/Disclaimer ________________________________________________________________________ 25
background
Page 4
2. Your Safety
This appliance is not intended for use by person/s (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and/or knowledge. Unless the person has been given supervision
or instruction concerning the use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance, it is not a toy.
Do not install Isodrive motor to a non-Schweigen and/or non-silent rangehood. If you fail to do so, your
warranty will be voided.
The manufacturer declines all responsibility in case of failure to adopt proper safety measures.
Ensure that the location in which this appliance is installed, has good and permanent ventilation.
Please consult local laws and regulations and install in accordance.
Use an electrical connector with earth that is correct for your location.
Check that the voltage in your area corresponds to the appliance as indicated on the rating label.
Before Installation
We recommend this appliance to be installed or repaired by a qualied Schweigen Home Appliances technician.
Please see our website www.schweigen.com.au for recommended installers.
It is dangerous to modify any part of this appliance. Modication of any kind, will immediately void the warranty.
Electrical Cord
Ensure the supply cord is not exposed to heat, chemicals or sharp objects. If the supply cord is damaged, it must be
replaced by the manufacturer, service agent or a similarly qualied person in order to avoid a hazard. The power
supply cord connection MUST BE installed in such a way that access is easy in case of emergency.
RECEIVING YOUR RANGEHOOD
Please read this section thoroughly before attempting to operate the appliance.
Inspect your product upon receipt. Any damage or defects MUST be reported
within 48 hours, or no claim will be recognised.
DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED.
If this product is installed damaged, the supplier, nor the retailer, will be responsible
for the costs associated with the repair, replacement, removal or re-installation of
the appliances.
background
Page 5
2. Your Safety
This guide is for the installation of the Isodrive motor system after the rangehood has been mounted on the
wall or roof. (Refer to rangehood installation manual on how to install the rangehood).
NOTE: All PVC pipe and exi ducting measurements are referring to inside measurements, unless otherwise
mentioned.
Motor Features
Roof and wall mounting with IPX4 degree of weather protection.
Super quiet, long vane, backward curved centrifugal fan.
Airow is dependant on installation and the ducting used. Using single 200mm ex duct, you should attain
up to 1600m
3
/hr. The use of a smaller than 150mm (ISD) pipe would result in a loss of airow and it is not
recommended.
Simple installation: The motor mounts onto a 150mm PVC pipe for ultimate strength and allows for easy
Dektite roof sealing.
Industrial quality motor and fan made in Germany and rated at 40,000 hours.
Motor is a high eciency PSC type and rated at 135W costing around the same as two 70W light globes to
run.
WARRANTY 10 YEARS return to manufacturer. Covers faulty manufacturing or components. It does not
cover normal wear and tear.
General Notes on Installation and Use
This fan unit is designed to be installed using 150mm (ISD) PVC pipe as the initial connection duct to the fan
module, and is supplied with a 150mm (ISD) PVC pipe to 200mm (ISD) exible duct
bell-mouth adaptor.
This fan is suitable for connection to ducting runs with a minimum inlet area of 22,000mm
2
and length up to 15
metres maximum (check with supplier if longer duct length required). Where possible exible ducting must be
extended suciently to present a smooth air passage with bends of at least the radii of twice the diameter of
the duct. Excessive bends in the ducting will compromised extraction.
WARNING: The rangehood must not be ducted into a wall cavity or a ceiling space, where a build up of grease
can occur and become a potential re risk. This will void warranty.
NOTE: Fan module and dual foil exi-duct are acoustically matched. Use of semi-rigid or rigid ducting will result
in increased noise and may void warranty. See installation instruction notes ‘Why exi-duct’.
Recommended Installation Distance
Isodrive 1600 motor, recommended 5 to 6 metres of exi ducting and with at least 2 bends.
NOTE: Although less than 5 to 6 metres will increase extraction power this will result in higher noise level.
Maximum duct length 15 metres. Check with supplier if longer duct length is required. Do not reduce the duct
size at any time and avoid sharp bends.
background
Page 6
Minimum Mounting Height
This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the
fan impeller) above a oor or the ground.
Avoidance of Back Flow
Care should be taken to avoid the back ow of gases into the room from the open ue of gas or other open re
appliances.
Safety of Children
This fan is not intended for use by young children or inrm persons without supervision.
Replacement of supply cord
If the supply cord is damaged, it must be replaced by a service agent or suitably qualied person in order to
avoid a hazard.
Why Flexi-duct
Some internet sites strongly recommend the use of rigid ducting over fully exible ducting. This
may well be the case with conventional rangehoods with internal motor rangehood but not with
external motor rangehood.
Schweigen’s unique Isodrive system works in the opposite way to conventional rangehoods, pulling air through
the hood and acoustically matched ducting, producing almost silent high volume ow. The use of a complete
rigid or semi-rigid ducting system will allow an organ piping eect to occur; like a didgeridoo where a noise is
produced at one end of a hollow rigid pipe and the noise is amplied out the other.
The Isodrive system places the noise outside the house.
WARNING: Installation without the use of at least the minimum recommended length of acoustically matched
exi-ducting in the system will void performance expectations. Any installation problem must be reported
to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer.
Schweigen takes no responsibility for problems caused by faulty installation, this may void warranty. A
preferred installer list can be obtained from Schweigen website www.schweigen.com.au or by calling
1300 881 693.
2. Your Safety
background
Page 7
3. Description
Isodrive Motor
Included in the box:
1. Isodrive 1600 motor (405W x 220H mm approx.)
Approx. 3 metre, 10amp cable and standard male plug
2. Fire resistant 150mm (160mm OD
1
) PVC riser pipe
Note: Cable cut-out at the bottom end only
3. Flexible ducting
Approx. 6 metres, 200mm (210mm OD
1
) diameter
4. Bell-mouth adopter ring
200mm duct to 150mm riser
5. Weather Shield
Should be installed to prevent rain/water entering the unit
6. Back Draught Shutter
Not included in the box:
Roof seal kit / Dektite
Support straps for poly pipe which connects to the
roof truss
Aluminium Foil tape
Hanging Bracket require for wall mount
Wall Cover Plate (wall mount only)
Zip ties
1
OD refers to outside dimension.
1
5
2
3 4
6
NOTE
For more exible ducting instructions, refer page 19.
background
Page 8
4. Installation
Roof Installation
Recommended duct length: 1600 motor — 5 to 6 metres.
Mount 150mm (ISD) rigid PVC pipe securely to beams, trusses or other appropriate structures: refer gure 1.
The pipe should be mounted vertically with the roof penetration being sealed using a Dektite or other appropriate
sealing membrane or device.
Ensure that the PVC pipe protrudes at least 50mm past the top of the Dektite, checking that the fan assembly
clears the roof cladding at upper edge, refer gure 1.
Pass power cord and plug through mounting ange and pipe, then out the slotted PVC pipe for connection to the
female plug coming from the canopy/rangehood. Refer to gure 4.
Do not insert plug into socket outlet or switch on until installation has been completed. Fit fan module to pipe and
x in position using side locking screw.
Certain external installation congurations may cause audible levels of noise to be heard due to the air being
expelled from the motor. To minimize external noise disturbance you can use between 6 to 15 metres of exi duct
to place the Isodrive motor in an appropriate position.
Please be aware that the 1600 motor is capable of expelling air at 1600m
3
/hr.
For more information on environmental noise limit and conditions please contact your local Council. We have a list
of recommended installers available on the Schweigen website.
Do not install the exi ducting in a straight line and minimum of two gentle bends in the ducts is required.
background
Page 9
4. Installation
1600 motor
Figure 1 Roof Mount Option
Pipe protrusion above dektite
Fix fan module using side
locking screw
Weather shield attachment
(only for 1600 motor)
Connect to
rangehood
Connect to power supply
NOTE: Prevent any cord bunching by
pulling cord through from plug top end
NOTE: Minimum ducting length
4 metres. Fully extend exible
ducting, cut to length.
Fit side supports to locate pipe
Strap to supports
Power Cord
Dektite
150mm PVC Pipe
(Locking holes fan end)
Bell-mouth Adaptor
50mm
background
Page 10
1.
Wall Installation
This type of installation is similar to roof mounting, ensuring that the pipe extends at least 50mm past the wall
surface refer gure 2. If the pipe length is shortened, reproduce the power cord exit slot on the inside of the
wall.
IMPORTANT FOR 1600 MOTOR: Weather shield must be tted to the top cover of the side ange using
the 3 screws provided. Also, it is required to use the hanging bracket for wall mount installation, for more
information please refer to page 15.
NOTE: By decreasing the length of the exi duct from which specied (refer to installation instructions) there
will be an increase in airow and noise levels as a result. This increase in airow can cause movement of air to
be heard through the system and inhibit the system to run silently.
Installation Without Back Draught Shutter
Figure 2 Wall Installation
Wall
Wall Optional
Fitment Pipe
Weather shield
must be at top
(1600 motor only)
Optional Mounting Flange
(P40113MF*)
150mm PVC Stormwater Pipe
From outside face of ange to end of pipe (or
wall if mounting ange not used)
50
50
Locking screws to be fully
tightened engaging in holes
Locking holes at 4 and 10 o’clock
Locking screws
Power cord to
240V supply
Seal with silicone or
urethane
Fill gap between pipe
and wall or t second
wall mount ange if
required
1600
motor
*Optional wall mounting ange (P40113MF) is available
from Schweigen, please contact 1300 829 066.
4. Installation
background
Page 11
1.
IMPORTANT: When
mounting pipe fan
locking holes to be in
outside end of pipe (fan
end)
Min 150mm long
150mm PVC pipe
Locking Screw
Min 50mm
Flexible 200mm
ducting
Bell-mouth Adaptor
Locking holes at 10 and
4 o’clock
Cord slots at bottom
(6 o’clock position)
Weather shield
upper most
NOTE: Ensure that power cord is fed through exit slot and
is not allowed to double back restricting fan inlet.
Attach weather shield using 3 screws provided
when wall mounting. Ensure weather shield is
upper most position (12 o’clock position) when
engaging locking screw
Fix fan module using side locking
screw at 4 & 10 o’clock
Figure 3 Wall Mount Option
1600 motor
1600 motor
4. Installation
NOTE: Ensure that power cord
is fed through exit slot and is
not allowed to double back
restricting fan inlet.
background
Page 12
Installation Through Wall with Back Draught Shutter
Due to the weight and to create stability for the Isodrive 1600 motor, it is require to use a hanging bracket.
Warranty will be void if a hanging bracket is not used.
Figure 7
*Optional parts are available from Schweigen, please contact 1300 829 066.
Shield
Hanging Plate
Hanging Plate
Power Cord
Hanging
Plate
Hanging Bracket P1107*
NOTE: Hanging bracket is required
Shutter Assembly
Optional wall cover plate with
notch at bottom P1108*
Minimum pipe protrusion
from wall surface
Height of hanging bracket
above top of pipe
Slot in pipe at bottom
(6 O’Clock)
Optional wall cover plate P1108*
Required Hanging Bracket
P1107*
Shield
47mm
90-
95mm
Wall
Ensure that power
cable passes through
the cover plate notched
recess and is clear of
cut edges
Hanging bracket may be
substituted in the eld
by 25mm x 6mm at
bar bent to form angle
bracket
4. Installation
background
Page 13
Figure 4
Flat Roof Installation
Flat roof mounting using optional mounting ange*.
PED
Engage locking
screws in holes
Seal 3 holes in
stepped surface
Seal between mounting
ange and cover
Up-stand and
capping
Power supply cord
passing through
pipe slots
NOTE: Cut 150mm PVC
stormwater pipe to length and
reslot ducting end. Ensure that fan
end locking holes remain
200mm Flexible
Ducting
Seal top edge of ange
50
Protrusion of pipe above
mounting ange
Bond ange to pipe using
silicone, urethane or type ‘N’
PVC solvent cement
Optional mounting ange
P40113MF*
Roof Cladding
1600
motor
*Optional wall mounting ange (P40113MF) is available
from Schweigen, please contact 1300 829 066.
Hanging Bracket P1107*
NOTE: Hanging bracket is required
4. Installation
IMPORANT
It is a requirement to use the hanging bracket for all wall mount installations.
Please refer to the manual for more information.
background
Page 14
Fan Unit Shutter Assembly for Isodrive 1600
1. Assemble by tting shutter assembly into fan inlet shroud moulding, ensuring that attaching screws align
with holes. Alignment can be checked visually by folding in shutter aps.
2. Fully tighten both screws and re-check tment into holes.
3. Fit assembly to duct pipe as per installation instructions supplied.
Attaching screws
Attaching hole
Inlet fan moulding
Shutter Assembly
NOTE: With through wall installations ap
shaft will be close to vertical
Figure 8
4. Installation
background
Page 15
Twin Motor Installation (suitable for rangehoods with two 200mm outlets)
Where two motors are to be used, follow the method below. Each motor should have a separate ue pipe. Refer
gure 9. The two motors can be wired by an electrician.
Connect to main power
Connect to motor
Computer
box
Connect to 150mm
ducting adaptor
Rangehood
Cover
Use smooth owing curves for
maximum airow. Remove excess
ducting by trimming to length.
Note: Do not install exi ducting in a
straight line
Must have separate
ue pipe for twin fan
installation
Z: Minimum distance between the
two fans is 600mm.
Connect to rangehood
Z
Figure 9 Roof mount option
1600 motor
4. Installation
background
Page 16
Figure 10 Roof mount option
Twin Motor Installation (suitable for rangehoods with one 200mm outlets)
Where two motors are to be used and there is only one 200mm outlet, follow the below methods for each
motor then join into the “Y” piece prior to joining ducting to the canopy / rangehood. Refer gure 10.
The two motors can be wired by one of the following methods:
Wired into one plug by an electrician
A double adaptor plugged into the lead from the canopy / rangehood
A double GPO powered from the canopy
Cover
Try to keep length of
exible ducting as even
as possible other wise
motors will draw air o
each other
Ensure exible ducting
is fully extended and as
short as possible. Use
smooth owing curves for
maximum air ow. Remove
excess ducting by trimming
to length.
‘Y’ Junction for Twin 900/1600
Fan Installation
200 x 200 x 200mm
Multi-t Y joint to be used with all
twin 1600 motor installation where
the rangehood has only one 200mm
opening
If multi-t Y joint is supplied
you will need to cut ducting to
length.
1600 motor
Z: Minimum distance
between the two fans
is 600mm.
Z
4. Installation
background
Page 17
Figure 11 Roof mount option
Single Motor Installation Twin 200mm Outlet
(suitable for rangehoods with two 200mm outlets and one 1600 Isodrive motor)
This is for use where one motor is to be used and there are two 200mm outlets, refer gure 11.
Try to keep length of
exible ducting as even
as possible other wise
motors will draw air o
each other
Ensure exible ducting
is fully extended and as
short as possible. Use
smooth owing curves for
maximum air ow. Remove
excess ducting by trimming
to length.
200 x 200 x 200mm
If multi-t Y joint supplied you
will need to cut to size.
1600 motor
4. Installation
background
Page 18
5. Measurements
Measurements for Isodrive 1600
(Not to Scale)
148mm
90mm
35mm
405mm
220mm
440mm
160mm
225mm
190mm
Dektite
Motor weight: 6kg net.
Shutter assembly is not shown in the diagram.
background
Page 19
6. Flexible Duct
Flexible Ducting
Flexible ducting must be fully extended and cut to the required length upon installation. Maximum fan
performance will not be achieved unless the ducting is fully extended. Failure to fully extend ducting results in
a smaller air passage and lower airows. Incorrect installation may reduce airow or increase noise levels. Call
outs relating to incorrect installation will result in a service fee directed to the customer. Schweigen will take no
responsibility for problems caused by faulty installation. A list of preferred Schweigen installers can be
obtained from the Schweigen website www.schweigen.com.au.
Please keep the exi ducting taut, 5
to 6 metres in length with two gentle
bends in the ductings.
NOTE: In shallow roof spaces
extend exi ducting horizontally
1600 motor
background
Page 20
6. Flexible Duct
Shallow Roof Space
In shallow roof spaces, do not crush or kink exible ducting, as it will reduce air ow severely. 90 degree curve
made of PVC or galvanise can be used as a substitute for the bend, refer to gure 12.
Figure 12
Figure 13
Use 90 degree curve
PVC or galvanise curve to
prevent crushing
Important Note
Please do not crush or kink exible ducting, as it will reduce air ow and may cause noise to occur through the
system. Ducting needs to be kept taut at all times.
background
Page 21
6. Flexible Duct
Securing Flexible Duct
Flexible duct must be installed with supports at maximum intervals of 1.5 metres. Flexible ductwork can be
supported by using good quality gaer or aluminium foil tape. Provided that it does not restrict the internal
diameter of the ducting. Ducting installed looped over hanging beams should be installed in such a manner
as to ensure the changes of direction are gradual. Support of the ducting with the use of hangers may be
required, see option 2.
NOTE: Ducting should be kept taut at all times.
Figure 14 Examples of securing ducting
Option 1
Secure the exible duct
to the beam
Option 2
Support exible duct
by using hangers.
NOTE: Care shall be
taken to minimize
sagging or snaking
of the duct between
supports.
Aluminium foil
tape
Aluminium foil tape
Hanger
background
Page 22
7. Parts List
Parts List for Isodrive 1600
9
3
1
5
4
6
7
3
18
19
20
21
22
23
17
16
11
12
13
14
15
24
25
2
10
23a
OR
For wall installation with
no back drought system
or at roof installation.
background
Page 23
7. Parts List
Parts List for Isodrive 1600
Number Part Number Description Quantity
1 P1120 M4X160mm Pan Head Screw 4
P1120N M4 KEPS Nut (not shown in gure) 4
5 P1114 Capacitor 3.5μF 1
9 P1100 Fan Motor Mounting Bracket 1
10 P1102 Fan Base Spinning 1
11 P1113 Heyco Snap Bushing 1
12 P40113 Base Moulding 1
13 P1124 M4X12mm Hex Washer S/T Screw 11
14
200MM BDSS
BUILD ASS
Shutter Assembly 1
15 P1111 Power Cable 3 Core 1
16 P1101 Fan Top Spinning 1
17 P1104 Side Mount Cover Weather Shield 1
18 P1105 Fan Guard 1
19 P1126 M4X8mm Machine Screw with Spring Washer 4
20 P1110R Centrifugal Fan/Motor Unit 1
21 P1106 Hanging Plate 1
22 P1107 Hanging bracket (Optional) 1
23 P1108 Wall Cover Plate (Optional) 1
23a P40113MF Mounting Flange (Optional) 1
24 P1069 Slotted Pipe (150mmX455mm) 1
25 P40114 Bell Mouth Adaptor 1
background
Page 24
8. Maintenance
Roof Restoration or Cleaning
Before doing your roof restoration or cleaning, please completely cover the outside motor system and avoid all
chemical contact.
IMPORANT
Any damages caused by the
use of chemical products are
not covered by warranty.
Figure 15 Avoid chemical contact to motor system
background
Page 25
9. Warranty / Disclaimer
Warranty
(See warranty for more information)
Isodrive motor has a 10-Year replacement product warranty. The consumer is responsible for any charges
associated with removal of the faulty unit and installation of the new unit. The customer is also responsible for
any freight charges incurred in this change over process.
Disclaimer
Under our policy of continuous product development, product specications may change without notice.
Prospective purchasers should therefore check with the retailer to ensure this publication correctly describes
the products being oered for sale. All information supplied is to be used for general reference purposes only
and is on the understanding that Schweigen Home Appliances will not be liable for any loss, liability or damage
of whatever kind arising as a result of any reliance upon such information. All pictures used in the guide are for
illustrative purposes only.
background
Page 26
Notes
background
Page 27
Notes
background
Distributed by:
8/3-4 Anzed Court,
Mulgrave 3170 Victoria.
1300 881 693 (EST)
www.schweigen.com.au

Specifications

Schweigen GA-1200SEPAK Questions and Answers