En-6
How to set to blow out air from the upper and lower air outlets.
Air Outlet Selection switch
Upper airow Upper and lower airow
NOTES:
Set the air outlet selection switch to the end. Otherwise, air outlet
cannot be selected as intended.
Description of operation
Operation Mode Airow Conditions
Cooling
Upper and lower
airow
Room temperature and set
temperature are di󰀨erent.
Upper airow
Room temperature is close
to set temperature, or the air
conditioner has operated for
1 hour.
Dry
Upper and lower
airow
-
Heating
Upper and lower
airow
Airow temperature is high
Upper airow
Airow temperature is low.
(During defrosting operation,
start of operation, etc.)
6. TIMER OPERATIONS
NOTES: When [
] indicator on the indoor unit blinks, set the clock
and timer again. This blinking shows that the internal clock go
wrong due to an interruption of the power supply. (Refer to
page 11.)
Timer setting procedure
Before setting the timer, please adjust the clock. (Refer to “remote
controller preparation”).
1. Press
.
on the remote controller display will blink.
2. Press
()
to choose timer operation.
The timer operation will change as follows:
[]
[]
[]
Weekly timer
Enables you to set operation
schedules up to 4 setting for each
day of the week.
On timer
Starts the operation at your desired
time.
O󰀨 timer
Stops the operation at your desired
time.
Program timer
Operates as the combination of the
On timer and O󰀨 timer.
Sleep timer
Supports your comfortable sleep
by moderating the air conditioner
operation gradually.
3. Press
.
4. Set each timer operation.
For details, refer to the following instructions of each timer setting.
5. Press
to complete the timer setting.
Be close to the indoor unit.
To cancel the timer setting during the procedure, press
again.
5.2. Airow direction setting
For details of the airow ranges, refer to “Airow direction
range”.
Up and down airow direction setting
)
Press
to adjust the Up and down airow direction.
Left and right airow direction setting
CAUTION
Before you adjust the left and right airow direction,
make sure that the up and down airow direction louver
has been stopped completely.
)
Adjust two knobs by hand.
Swing operation setting
)
Press
to start/stop the Swing operation.
NOTES: The Swing operation may stop temporarily when the indoor
unit fan is rotating at very low speed or is stopped.
Airow direction range
Up and down airow direction
Change by
1
2
3
4
5
Swing operation by
1 5
NOTES:
Do not adjust the airow direction louvers by hand.
In the Auto or Heating mode, the airow direction stay position 1 for
a while from the start of the operation.
When indoor unit is embedded in a wall, airow is xed to horizontal
direction 5.
Please ask the service personnel to perform the embedding in a
wall.
Vertical louver Adjustment
Adjust the vertical louver.
Move the vertical louver to adjust airflow in the direction you
prefer.
CAUTION
Always adjust the vertical louver when the damper is
open. Opening the damper forcibly with hands can
cause damper to malfunction.
Air outlet selection
With this function, air come out simultaneously from the upper
and lower air outlets so that the room can be cooled or heated
e󰀨ectively. This function is set using the switch behind the front
grille of the Indoor unit. (This function is available in cooling and
heating operation.)