23
4. Use UL listed wire connectors and connect white wires
(B) together.
NOTE: The green (or green/yellow) ground wire in the conduit
from the in-line blower motor system is to be connected with
the green (or bare) wire of the home power supply cable and
with the green/yellow wire (A) in the terminal box.
5. Connect green (or bare) ground wire from home power
supply to the green/yellow ground wires (A) in terminal box
using UL listed wire connectors.
6. Install terminal box cover.
7. Reconnect power.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
Check Operation
1. Push and hold the button on the top of the downdraft vent
for a few seconds. The retractable section of the downdraft
vent will rise and the blower will be able to start using the
control slider. Remove any protective film and use a stainless
steel cleaner to clean any remaining grease. Position the top
trim over the retractable section and snap trim into place.
Trim kits for matching your cooktop color are available from
your dealer.
For information on ordering, see the “Assistance or Service”
section.
2. Slide the control slider on the side of vent to check the
operation and speed of the blower.
3. If the blower does not operate:
Check that filter or filters are pressed in as far as they
will go.
Check that the circuit breaker has not tripped or
a household fuse blown.
4. Connect vent system to blower. Vent system must end with
a wall or roof cap. Use clamps or duct tape to seal all joints.
NOTE: To get the most-efficient use from your new retractable
downdraft vent, read the “Vent System Use” section.
A
B
D
E
C
A. Top trim
B. On/Off button
C. Blower control slider
D. End cap
E. Filters
Loading ...
Loading ...