INSTALLATION
INSTRUCTIONS
. .
Four
Conductor
Wire
Connection
to
Range
Electrical
Connection
to
the
Where
local
codes
does
NOT
permit
connection
of
the
Range
(U.S.A.)
frame
grounding
conductor
to
the
neutral
wire
of
the
Three
Conductor
Wire
Connection
to
Range
©oPPer
power
supply
cord
(see
Figure
4):
If
local
codes
permit
connection
of
the
frame
grounding
conductor
to
the
neutral
wire
of
the
copper
power
supply
cord
(see
Figure
3):
1.
Remove
the
3
screws
at
the
lower
end
of
the
rear
wire
cover,
then
bend
the
lower
end
of
the
rear
wire
cover
(access
cover)
upward
to
expose
range
terminal
connection
block
(see
Figure
2).
2.
Using
the
nuts
supplied
in
the
literature
package,
connect
the
neutral
of
the
copper
power
supply
cord
to
the
center
silver-colored
terminal
of
the
terminal
block,
and
connect
the
other
wires
to
the
outer
terminals.
Match
wires
and
terminals
by
color
(red
wires
connected
to
the
right
terminal,
black
wires
connected
to
the
left
terminal)
(see
figure
3).
3.
Lower
the
terminal
cover
and
replace
the
3
screws.
Silver
Colored
Terminal
Red
Wire
Terminal
Block
Grounding
Strap
1
1/8"
(2.9
cm)
Dia.
Direct
Connection
Hole.
Punch
Out
A
User
Supplied
Strain-relief
Must
Be
Installed
at
This
ee
Knockout
for
1
3/3"
Location.
P
(3.5
cm)
Dia.
Cord
.
Kit
Hole.
Figure
3
1.
Remove
the
3
screws
at
the
lower
end
of
the
rear
wire
cover,
then
raise
the
lower
end
of
the
rear
wire
cover
(access
cover)
upward
to
expose
range
terminal
connection
block
(see
figure
2).
2.
Remove
the
grounding
strap
from
the
terminal
block
and
from
the
appliance
frame.
3.
Using
the
nuts
supplied
with
the
literature
package,
connect
the
ground
wire
(green)
of
the
copper
power
supply
cord
to
the
frame
of
the
appliance
with
the
ground
screw,
using
the
hole
in
the
frame
where
the
ground
strap
was
removed
(see
Figure
4).
4.
Connect
the
neutral
of
the
copper
power
supply
cord
to
the
center
silver-colored
terminal
of
the
terminal
block,
and
connect
the
other
wires
to
the
outer
terminals.
Match
wires
and
terminals
by
color
(red
wires
connected
to
the
right
terminal,
black
wires
connected
to
the
left
terminal).
5.
Lower
the
terminal
cover
and
replace
the
3
screws.
Terminal
Block
Silver
Colored
Terminal
vA
>
ti
=
IK
a)
((
1
1/8"
|
Dia.
Direct
Connection
Hole.
Punch
Out
Knockout
(White
Wire)
for
1
3/8"
(3.5cm)
Dia.
Ground
(Bare
Cord
Kit
Hole.
Copper
Wire)
A
User
Supplied
Strain-relief
Must
Be
Installed
at
This
Location
To
240
V
Receptacle
NOTE:
Be
sure
to
remove
the
supplied
grounding
strap,
Figure
4
Loading ...