20
| Maintenance
Napoleon.com | BUILT-IN Series
Maintenance
Maintenance Instructions
WARNING! Keep the grill away from combustible materials, gasoline, and other flammable vapors and liquids.
!
WE WANT
TO HELP!
Contact the Napoleon
Customer Solutions
Department for
recommended
replacement parts.
+31 345 588655.
Burner Port
Yellow Tip
Dark Blue
Light Blue
Recommendations
This grill should be thoroughly inspected and serviced annually by a qualified service person.
• Do not obstruct the flow of ventilation and combustion air.
• Keep the cylinder enclosure ventilation openings located on the side of the cart or enclosure and front and back of the
bottom shelf clear from debris.
FLAME APPEARANCE
!
IMPORTANT! Orifice changes and air shutter adjustments
must always be done by a qualified gas installer.
• The flames should always look dark blue, tipped with light blue and
occasionally yellow.
• Too little air flow to the burner will produce soot and lazy yellow
flames.
• Too much air flow to the burner will cause flames to lift erratically
and cause igniting difficulties. See “Troubleshooting”.
• The air shutter is factory set and should not require adjusting under
normal conditions. Adjustments might be required under extreme
field conditions.
Note: Infrared burners have no air adjustment.