Kenmore 10658329800 Official Side-by-side Refrigerator

User Manual - Page 23

For 10658329800.

PDF File Manual, 72 pages, Download pdf file

Loading ...
Loading ...
Loading ...
PERFORMANCE DATA SHEET
Base Grille Water Filtration System
Model T1 KB2/T1 RFKB2 Capacity 200 Gallons (757 Liters) without Filter Indicator Light
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction
of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the
reduction of Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity,
Asbestos, Lindane, Tetrachloroethylene, Endrin, Alachlor, Chlorobenzene and Ethylbenzene.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSl Standards 42 and 53.
Substance Reduction NSF Reduction Average Influent Challenge Maximum Average Minimum %
Aesthetic Effects Requirements Influent Concentration Effluent Effluent Reduction
Chlorine Taste/Odor 50% reduction 2.0 mg/L 2.0 mg/L + 10% 0.08 mg/L ** 2.0 mg/L 95.93
Particulate Class I* 85% reduction 3533333#/mL At east 1O,OOOpart c es/mL 22000 #/mL 11567 #/mL 99.38
Contaminant NSF Reduction Average Influent Challenge Maximum Average Minimum %
Reduction Requirements Influent Concentration Effluent Effluent Reduction
Lead: @ pH 6.5 0.010 mg/L 150 ug/L 0.15 mg/L + 10% 1.0 ug/L 1 ug/L 99.33
Lead: @ pH 8.5 0.010 mg/L 157 ug/L 0.15 mg/L _+10% 2.0 ug/L 1.08 ug/L 98.72
Mercury: @pH 6.5 0.002 mg/L 0.0058 mg/L 0.006 mg/L + 10% 0.0002 mg/L 0.0002 mg/L 96.53
Mercury: @pH 8.5 0.002 mg/L 0.0057 mg/L 0.006 mg/L _+10% 0.0002 mg/L 0.0002 mg/L 96.5
Benzene 0.005 mg/L 15 ug/L 0.015 mg/L _+10% 0.5 ug/L 0.5 ug/L 96.67
O-Dichlorobenzene 0.6 mg/L 1750 ug/L 1.8 _+10% 1.0 ug/L 1.0 ug/L 99.94
Toxaphene 0.003 mg/L 15 ug/L
Atrazine 0.003 mg/L 10 ug/L
Asbestos 99% 101 MFL
Live Cysts _ >99.95% 120,000/L
Turbidity 0.5 NTU 11.4 NTU
Alachlor 0.002 mg/L 41.3 ug/L
Endrin 0.002 mg/L 5.9 ug/L
Ethylbenzene 0.7 mg/L 1867 ug/L
Lindane 0.002 mg/L 1.9 ug/L
Chlorobenzene 0.6 mg/L 2.0 ug/L
Tetrachloroethylene 0.005 mg/L 14.2 ug/L
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted.
Temp. = 68°F to 71.6°F (20°C to 22°C).
0.015 + 10%
0.009 mg/L _+10%
107to 108fibers/U t
50,000/L min.
11 _+1 NTU
0.04 _+10%
0.006 + 10%
2.1 _+10%
0.002 _+10%
2.0 _+10%
0.015 _+10%
1.Oug/L
2 ug/L
0.17 MFL
8/U
0.41 NTU
0.2 ug/L
0.5 ug/L
0.70 ug/L
0.02 ug/L
0.0005 ug/L
0.5 ug/L
1.O ug/L
2 ug/L
0.17 MFL
1/U
0.24 NTU
0.2 ug/L
0.3 ug/L
0.0588 ug/L
0.02 ug/L
0.0005 ug/L
0.5 ug/L
93.33
80.8
99.83
99.99
96.4
99.52
91.5
99.96
98.93
99.98
96.47
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Average %
Reduction
97.36
99.67
Average %
Reduction
99.33
99.31
96.53
96.5
96.67
99.94
93.33
80.8
99.83
>99.99
97.89
99.52
95.47
100
98.93
99.98
96.47
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model TIKB2: Change the water filter cartridge every 6 months.
If the water flow to the water dispenser or ice maker decreases
noticeably before 6 months have passed, replace the water filter
cartridge more often.
Use replacement cartridge T1 RFKB2, part #9030. In Canada, use
replacement cartridge T1 RFKB2, part #9030B. 2008 suggested
retail price of $44.99 U.S.A./S50.99 Canada. Prices are subject to
change without notice.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Refer to the front cover or "Accessories" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate 0.5 gpm (1.9 L/min) @ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
ttFibers greater than 10 um in length
€Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
23
Loading ...
Loading ...
Loading ...