en Installation and connection
50
Warm water connection*
Ho t wa t e r connect i on
* depending on the configuration of
your specific dishwasher
The dishwasher can be connected to
cold or hot water up to max. 60°C.
Connection to hot water is
recommended if the hot water can be
supplied by energetically favourable
means and from a suitable installation,
e.g. solar heating system with
circulation line. This will save energy
and time. The hot water setting :‹‚
allows you to adjust your appliance
optimally to operation with hot water. It
is recommended to have a water
temperature (temperature of the
incoming water) of at least 40 °C and
no more than 60 °C. It is not
recommended to connect the appliance
to hot water if the water is supplied from
an electric boiler.
Here’s how to change the hot water
setting:
1. Switch on ON/OFF switch (.
2. Hold down the programme button
# and then repeatedly press the
START button ` until :...
appears in the display window.
3. Release both buttons.
The LED of the # button flashes
and the digital display h lights up
to show the value :....
4. Press the programme button #
repeatedly until the factory setting
value :‹‹ appears in the display
window h.
5. By pressing the 3 button, you can
switch the hot water setting off :‹‹
or on :‹‚.
6. Press START button `.
The set value is saved.
Electrical connection
Connect the appliance to an
alternating current only, ranging from
220 V to 240 V and 50 Hz or 60 Hz
via a correctly installed socket with
protective earth conductor. See
rating plate for required fusing 9:.
The socket must be near the
appliance and freely accessible
following installation.
If the plug is not freely accessible, an
allpole disconnector with a contact
opening of at least 3 mm must be
fitted on the installation side to
satisfy the relevant safety
instructions.
The connection may be modified
by technicians only.
A power cord extension may be
purchased from customer service
only.
Use only a residual current operated
circuit-breaker which features the
symbol . Only this extension
guarantees compliance with
the currently valid regulations.
The appliance features a water
damage protection system. Please
note the system will function only
when the power supply
is connected.