Operation of Current Device
(Applicable to the unit adopts current detection device only )
Note: Performance may be reduced
outside of these operating
temperatures.
WARNING (for using R290/R32 refrigerant only)
-Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
-The appliance shall be stored in a room without continuously operating ignition sources
(for example: open ames, an operating gas appliance) and ignition sourcesor (for example:
an operating electric heater) close to the appliance. The appliance shall be stored in a room
without continuously operating ignition sources (for example: open ames, an operating
gas appliance or an operating electric heater).
-Do not pierce or burn.
-Be aware that the refrigerants may not contain an odour.
-Compliance with national gas regulations shall be observed.
-Keep ventilation openings clear of obstruction.
-The appliance shall be stored so as to prevent mechanical damage from occurring.
-A warning that the appliance shall be stored in a well-ventilated area where the room size
corresponds to the room area as specied for operation.
-Any person who is involved with working on or breaking into a refrigerant circuit should
hold a current valid certicate from an industry-accredited assessment authority, which
authorises their competence to handle refrigerants safely in accordance with an industry
recognised assessment specication.
NOTE:
Do not use this device to turn the unit on or o.
Always make sure the RESET button is pushed in for correct operation.
The power supply must be replaced if it fails reset when either the TEST button is
pushed, or it cannot be reset. A new one can be obtained from the product manufacturer.
If power supply cord is damaged, it cannot be repaired. It MUST be replaced by one
obtained from the product manufacturer.
NOTE:This air conditioner is designed to be operated under condition as follows:
The power supply cord contains a current device that senses damage to the power cord.
To test your power supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST
button, you will notice a click as the RESET button pops out.
3. Press the RESET button, again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this
it also indicated by a light on the plug head.)
Page 6
Cooling
operation
Outdoor temp:
Indoor temp:
Heating
operation
Outdoor temp:
O
O
23-76 F/ C-5-24
Indoor temp:
O
32-80 F/
O
0-27 C
O O O O
64-109 F/18-43 C (64-125 F/18-52 C
for special tropical models)
O
62-90 F/
O
17-32 C
Loading ...
Loading ...
Loading ...