Loading ...
Loading ...
Loading ...
Electrical connection
,
All electrical work must be performed by a
qualified service technician in accordance with
applicable codes and standards.
When installaing a residual current device (RCD) a
Type B GFCI circuit breaker must be installed.
The connecting terminal is located behind a cover.
The machine must only be connected to the voltage
and frequency shown on the data plate.
The machine is equipped with a multi-tap
transformer.
Steam heated washers are factory set to
3 phase, 208 V, 60 Hz
They can be converted to
3 phase, 240 V, 60 Hz by a Miele Service Technician.
Electrically heated washers are factory set to 3
phase, 230 V, 50/60 Hz
They can be converted to
3 phase, 208 V, 60 Hz by a Miele Service Technician.
Equalizer
Secure the potential equalizer, if necessary.
To activate the heating the water level in the drum
must be 4
5
/
16
" (110 mm) high.
A motor overload protection is located in the motor
winding.
See the enclosed wiring and installation diagrams.
Steam connection
The steam connection must only be connected by a
certified installer. For more information see the
enclosed installation plan and the installation manual.
Connecting the dispensing pumps
The connecting terminal for 4 time controlled
dispensing pumps is located behind the cover next to
the electrical connection. See the supplied wiring
diagram.
The dispensing pumps can be operated without the
multifunction module.
Installation Instructions
39
Loading ...
Loading ...
Loading ...