17
English
To Turn Off Imaging Thermometer
1. To turn off the imaging thermometer, push the menu/power
button (L) and hold for 3 seconds. The imaging thermometer will
also automatically turn off after 10 minutes of non-use.
2. Slide lens cover (G) up to protect lens when not in use.
Operating Tips
Use only D
E
WALT 12V Max* lithium-ion battery.
Ensure the D
E
WALT battery is in good working condition. If the
battery fuel gauge on the screen is empty, the battery needs to be
recharged.
Avoid sudden changes in temperature such as when entering or
leaving a heated building on a cold day as this can cause condensation
inside the imaging thermometer. To prevent condensation, place the
imaging thermometer in the kitbox or a plastic bag before exposing it
to sudden changes in temperature.
MAINTENANCE
Cleaning
WARNING: Blow dirt and dust off with clean, dry air at least once
a week. To minimize the risk of eye injury, always wear ANSI Z87.1
approved eye protection when performing this.
WARNING: Do not apply solvents to the lens as this may cause
damage. Do not clean the infrared lens too vigorously as this can
damage the delicate anti-reflective coating.
WARNING: Never use solvents or other harsh chemicals for
cleaning the non-metallic parts of the tool. These chemicals may
weaken the plastic materials used in these parts. Use a cloth
dampened only with water and mild soap. Never let any liquid get
inside the tool; never immerse any part of the tool into a liquid.
CHARGER CLEANING INSTRUCTIONS
WARNING: Shock hazard. Disconnect the charger from the AC
outlet before cleaning. Dirt and grease may be removed from the
exterior of the charger using a cloth or soft non-metallic brush. Do
not use water or any cleaning solutions.
Troubleshooting
Make sure the lens cover (G) is open.
Make sure the 12V Max* lithium-ion battery is charged.
Make sure the battery is installed on the handle set when in use.
If the screen freezes, remove the 12V Max* lithium-ion battery to
reset the unit. Reinsert the battery pack and press the power on
button.
KEY NOTES IF HAVING TROUBLE TAKING MEASUREMENT
1. Make sure to apply masking tape or flat black paint to surfaces
that are highly reflective (use the default 0.95 emissivity setting).
2. Make sure to have the correct emissivity for the material you
are testing. Refer to the Emissivity section and the Nominal
Emissivity Value table in this manual.
3. Clean the material before testing if there is heavy dirt, grease, etc.
Accessories
WARNING: Since accessories, other than those offered by
D
E
WALT, have not been tested with this product, use of such
accessories with this tool could be hazardous. To reduce the risk of
injury, only D
E
WALT recommended accessories should be used with
this product.
Recommended accessories for use with your tool are available
at extra cost from your local dealer or authorized service center.
If you need assistance in locating any accessory, please contact
D
E
WALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD
21286, call 1-800-4-D
E
WALT (1-800-433-9258) or visit our website
www.dewalt.com.