23
- NAT Gas / LPG / Butane Only.
NOTE: The Gas Regulator supplied is
convertible between Natural Gas
and LP Gas, but its outlet
pressure is fixed ex-factory and
is NOT to be adjusted.
- Town Gas Only.
1. Remove slotted cap from regulator.
2. Turn Ongas supply and appliance.
3. Adjust pressure adjusting screw to achieve correct burner
operating pressure.
NOTE: Measure operating pressure at manifold test point
with two burners operating at 'High Flame' setting.
4. Verify operating pressure remains correct (Re-adjust regulator
if required).
5. Screw cap nut back onto regulator.
On completion of gas conversion, replace gas type identification label located at:-
- Rear of appliance, above gas connection.
- Beside the rating plate.
Before leaving the installation;
1. Check all gas connections for leakage using soapy water or other gas detecting equipment.
2. Carry out a Commissioningcheck of appliance as shown in Installation Section of this manual.
3. Ensure any adjustments done to components that have adjustments / settings paint sealed are to be
re-sealed.
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
Pressure Adjusting
Screw
Cap Nut
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.