Loading ...
Loading ...
Loading ...
Rinnai 11 HotoElectricStorageWaterHeaterOIM
TABLE 2. RATINGS & OTHER SPECIFICATIONS
NOTE
APLVMUSTBEFITTEDIFTHEMAINSPRESSUREEXCEEDSTHELIMITSSHOWN.IFTHEMAINS
PRESSUREISWITHINTHELIMITSSHOWNFITMENTOFTHEPLVISOPTIONAL,HOWEVER,IT
ISRECOMMENDEDTHATTHEPLVISFITTEDINALLINSTALLATIONSASITAIDSWATERAND
ENERGYCONSERVATION.
Hoto
25L
Hoto
50L
Hoto
80L
Hoto
125L
Hoto
160L
Hoto
250L
Hoto
315L
Hoto
400L
Hoto 160L
Compact
Model Code HFE EHFA EHFD
Storage Capacity (L) 33 55 84 140 172 279 334 420 170
Hot Water Delivery (L) 25 50 80 125 160 250 315 400 160
Element Size (kW)
1.8, 2.4,
3.6
1.8, 2.4,
3.6
1.8, 2.4,
3.6
1.8, 2.4,
3.6
1.8, 2.4,
3.6
2.4, 3.6,
4.8
2.4, 3.6,
4.8
3.6, 4.8 2.4,3.6
Total Height (mm) A 452 694 900 1245 1620 1477 1770 1840 1313
Width incl. PTR Valve (mm) 490 490 590 590 564 674 674 744 600
Diameter (mm) B 415 415 515 515 500 605 605 675 537
Outlet Height (mm) C 297 524 685 1020 1419 1248 1541 1587 1107
Inlet Height (mm) D 153 158 225 225 162 210 210 237 186
Electrical Entry -
Lower (mm)
E 80 80 155 155 87 135 135 163 110
Electrical Entry -
Upper (mm)
F N/A N/A N/A N/A 1039 985 1225 1263 N/A
Packaged Weight (kg) 23 29 48 60 60 70 82 96 56
Boost Capacity
(Twin element only) (L)
N/A N/A N/A N/A 40 49 60 81 N/A
PTR Valve - included (kPa) 1000
ECV (kPa) 850
Max. Inlet Pressure
with ECV (kPa)
680
PLV with ECV (kPa) 500
Max. Inlet Pressure
without ECV (kPa)
800
PLV without ECV (kPa) 500
Max. Thermostat Setting
(°C)
70°C
Ingress Protection Rating IPX4
Electrical Supply 240V-@50Hz
Tank Body Colour White Dune
Hot and cold water
connection
Rp 3/4 (20mm)
SPECIFICATIONS
Loading ...
Loading ...
Loading ...