Dahua KTP02 IP Villa Door Station & Indoor Monitor

Digital VTH User's Manual V1.0.0 - Page 52

For KTP02.

PDF File Manual, 86 pages, Read Online | Download pdf file

KTP02 photo
Loading ...
Loading ...
Loading ...
46
Wire zone
Tap corresponding positions to set area type, NO/NC, alarm status, enter delay and exit delay.
Table 4-6 Parameter description
Parameter
Description
Area The number cannot be modified.
NO/NC
Select NO (normally open) or NC (normally closed) according to detector type. It
shall be the same as detector type.
Type
Select corresponding type according to detector type, including IR, gas, smoke,
urgency btn, door, burglar alarm, perimeter and doorbell.
Status
Instant Alarm: After armed, if an alarm is triggered, the device produces siren at
once and enters alarm status.
Delay Alarm: After armed, if an alarm is triggered, the device enters alarm status
after a specified time, during which you can disarm and cancel the alarm.
Bypass: Alarm will not be triggered in the area. After disarmed, this area will
restore to normal working status.
Remove: The area is invalid during arm/disarm.
24 Hour: Alarm will be triggered all the time in the area regardless of arm or
disarm.
A zone in Remove status cannot be bypassed.
Enter Delay
After entering delay, when armed area triggers an alarm,
entering armed area from non-armed area within the delay
time period will not lead to linkage alarm. Linkage alarm will
be produced if delay time comes to an end and it is not
disarmed.
Delay is only valid to
the areas of Delay
Alarm.
Exit Delay
After arm, Delay Alarm area will enter arm status at the end
of Exit Delay.
If multiple areas set the exit delay, screen prompt will conform
to maximum delay time.
Loading ...
Loading ...
Loading ...