Solutions to Common Problems
Semite Prevention Checklist
Before calling for service, review this list. It may save both time and expense. The list includes common
occurrences that are not the result of defective workmanship or materials in this dryer.
OCCURRENCE POSSIBLE CAUSE SOLUTION
Dryer does not start. Electrical power cord is not securely plugged Make sure the plug fits tightly in wall outlet.
in or plug may be loose.
House fuse blown or circuit breaker tripped. Reset circuit breaker or replace fuse.
Make sure electrical line is not overloaded and the
dryer is on a separate circuit.
Thermal limiter tripped. Call authorized service person for replacement.
LCD displays Dryer has been programmed to temporarily To return to the factory default settings, press and hold
n-_'3_'3 n'3_'3n-
ub,,u ,,,uuL. perform a repeating demo cycle, the temperature and dryness buttons at the same for 5
seconds.
Dryer runs but won't There are 2 house fuses in the dryer circuit. If 1 Replace fuse.
heat. of the 2 fuses is blown, the drum may turn but
the heater will not operate. (electric models)
Gas supply valve is not open (gas models). Check to make sure supply valve is open. See INSTAL-
LATION INSTRUCTIONS for procedure.
Dryer does not have enough air supply to See INSTALLATION INSTRUCTIONS.
support the burner flame (gas models).
LP gas supply tank is empty or there has Refill or replace tank.
been a utility interruption of natural gas (gas Dryer should heat when utility service is restored.
models).
Drying cycle takes too Lint filter is clogged with lint. Make sure all lint has been removed from the dryer lint
long, outside of the filter before starting each cycle.
dryer feels too hot or
smells hot. Exhaust duct requirements have not been Exhaust duct must be at least 4 inches in diameter and
met. made of rigid or semi-rigid metal.
When in place, the duct must have no more than
two 90 ° bends and must not exceed length listed in
INSTALLATION INSTRUCTIONS.
Electric dryer is connected to a 208 volt Drying time will be 20% longer than drying on a 240
circuit, volt circuit.
Drying procedures have not been followed. See "Operating Instructions."
Outside exhaust hood or exhaust duct may Clean out any obstruction.
be clogged or restricted.
High humidity. Use a dehumidifier near the dryer.