4.15 Replacing base socket plate
The base socket plate is located in the lower area at the front.
Prerequisite:
Appliance is disconnected from power supply.
Appliance is disconnected from water supply.
Furniture panel (optional) has been removed.
Outer door has been removed.
Outer door has been removed (fully integrated/integrated).
Toe panel has been removed (optional).→Page 227
4.15.1 Removing base socket plate
1. Remove two screws (1).
2. Disengage catch elements (2).
3. Tilt the base socket plate carefully forwards (1).
4.
Depending on the model series, the plug to the EmotionLight is still
secured to the base.
Unlock the plug on the catch tappet and pull to the rear (optional) (2).
4.15.2 Installing base socket plate
Install the base socket plate in reverse order.