JET HBS-1220MSA , 12" x 20" Semi-Automatic Mitering Variable Speed Bandsaw

Manual - Page 6

For HBS-1220MSA.

PDF File Manual, 36 pages, Read Online | Download pdf file

HBS-1220MSA photo
Loading ...
Loading ...
Loading ...
6
5.0 Specifications
Table 2
Stock number
424476 424475
Model number HBS-1220MSA HBS-1220MSAH
Motor and Electricals
Main motor type TEFC induction
Horsepower 3 HP (2.25 kW)
Phase 3 PH
Voltage 230/460 V (prewired 230 V)
1
Cycle 60 Hz
Listed FLA (full load amps) 8.5/4.2 A
Motor speed 1720 RPM
On/off switch Magnetic
Power transfer Drive belt with variable speed pulley
Power cable and plug
not supplied
Recommended circuit size
2
15 A
Sound emission
3
75 dB
Hydraulic motor 1/2 HP (0.37 kW), 3PH, 230/460V, 60Hz, 1.91/0.96 A
Vise operation manual hydraulic
Coolant pump 1/8 HP (0.09 kW), 3PH, 230/460V, 60Hz, 0.2/0.1 A
Capacities
Round
90 deg. 300 mm (11-13/16 in.)
45 deg. 285 mm (11-7/32 in.)
Square (WxH)
90 deg. 300 x 300 mm (11-13/16 x 11-13/16 in.)
45 deg. 285 x 285 mm (11-7/32 x 11-7/32 in.)
Rectangle (WxH)
90 deg.
420 x 300 mm (16-1/2 x 11-13/16 in.)
460 x 220 mm (18-1/8 x 8-5/8 in.)
490 x 100 mm (19-1/4 x 4 in.)
45 deg. 285 x 320 mm (11-7/32 x 12-9/16 in.)
Maximum jaw opening 500 mm (19-5/8 in.)
Blade size (WxTxL) 27 x 0.95 x 3960 mm (1 x 0.037 x 156 in.)
Blade wheel size (Dia. x W) Ø434 x 30 mm (17-3/32 x 1-3/16 in.)
Blade speed Variable, 90-370 SFPM
Gearbox 850 mL (1/4 gal.)
Hydraulic tank 1.5L (3/8 gal.)
Cutting fluid/coolant tank 39.9 L (10-1/2 gal.)
Main materials
Stand Steel
Bow Cast iron and steel
Blade wheels Cast iron
Bed Cast iron
Vise jaws Cast iron
General dimensions
Height of bed from floor 700 mm (28 in.)
Overall dimensions, assembled (LxWxH) 2210 x 800 x 1346 mm (87 x 31.5 x 53 in.)
Shipping dimensions (LxWxH) 2230 x 820 x 1350 mm (87.8 x 32.28 x 53.14 in.)
Weights
Net weight (approx.) 650 kg (1430 lb.) 659 kg (1450 lb.)
Shipping weight (approx.) 730 kg (1606 lb.) 739 kg (1625 lb.)
1
Conversion to 460V requires purchase of additional components. See sect. 7.1.
2
Subject to local and national electrical codes.
3
The specified values are emission levels and are not necessarily to be seen as safe operating levels. As workplace
conditions vary, this information is intended to allow the user to make a better estimation of the hazards and risks
involved only.
L = length, W = width, H = height, T = thickness, Dia = diameter, SFPM=surface feet per minute
Loading ...
Loading ...
Loading ...