Blue Seal Evolution GP518-LS Series 1200mm Gas Griddle Leg Stand

Installation Operation Manual - Page 25

For GP518-LS.

PDF File Manual, 29 pages, Read Online | Download pdf file

GP518-LS photo
Loading ...
Loading ...
Loading ...
23
- United Kingdom & EU (CE)
Category: II
2H3P
(20, 37), .II
2H3B/P
(20, 28-30),
Flue Type: A
1.
(*) Gas Control Valve is fitted with a non adjustable maximum flow bypass blanking
screw.
(**) Measure burner operating pressure at the gas control valve outlet test point with
burner operating at High setting. Operating pressure is ex-factory set, through
appliance regulator and is not to be adjusted, apart from when carrying out gas
conversion, if required. (Refer to Gas Conversion information in this section for
details).
GP513 GP514 GP516 GP518 GP513 GP514 GP516 GP518
Main Burner Injector 3.00mm 3.40mm 3.00mm 2.85mm 1.80mm 2.10mm 1.80mm 1.70mm
Pilot Burner Injector 0.41 0.25
Low Fire Adjustment 1 Turn 'Out' c.c.w.
High Fire Adjustment (*) Maximum Flow Screw. Fully In c.w.
Burner Operating Pressure (**) 8.2 mbar 8.5 mbar 8.2 mbar 26 mbar
Supply Pressure 20 mbar 37 mbar
Gas Regulator Cap Screw
GP513 GP514 GP516 GP518
Main Burner Injector 1.80mm 2.10mm 1.80mm 1.70mm
Pilot Burner Injector 0.25
Low Fire Adjustment 1 Turn 'Out' c.c.w.
High Fire Adjustment (*) Maximum Flow Screw. Fully In c.w.
Burner Operating Pressure (**) 26 mbar
Supply Pressure 28 - 30 mbar
Gas Regulator Cap Screw