Blue Seal Evolution G516C-B Series 900mm Gas Cooktop Bench Model

Installation Operation Manual - Page 6

For G516C-B.

PDF File Manual, 30 pages, Read Online | Download pdf file

G516C-B photo
Loading ...
Loading ...
Loading ...
4
- Australia
- New Zealand
- United Kingdom & EU (CE)
Category:
II
2H3P
(20, 37), .II
2H3B/P
(20, 28-30),
Flue Type: A
1.
* - Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be
adjusted, apart from when converting between gases, if required. (Refer to Gas Conversion
section for details).
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section
21 MJ/hr 21 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Gas Connection
See Gas Connectioninformation overleaf.
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section
21 MJ/hr 21 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Gas Connection
See Gas Connectioninformation overleaf.
Open Burner
(each)
Griddle
(each 300mm
section)
Open Burner
(each)
Griddle
(each 300mm
section)
Open Burner
(each)
Griddle
(each 300mm
section)
Heat Input (nett)
Nominal
6.5 kW 5.5 kW 6.5 kW 5.5 kW 8.0 kW 6.0 kW
Reduced
1.75 kW 1.85 kW 1.75 kW 1.95 kW 2.0 kW 2.0 kW
Gas Rate (nett)
Nominal
0.69 m
3
/hr 0.58 m
3
/hr 0.51 kg/hr 0.43 kg/hr 0.63 kW 0.47 kW
Reduced
0.19 m
3
/hr 0.20 m
3
/hr 0.14 kg/hr 0.15 kg/hr 0.16 kW 0.16 kW
Supply Pressure 20 mbar 37 mbar 28 - 30 mbar
Burner Operating Pressure (*) 9.5 mbar 26 mbar
Gas Connection See Gas Connectioninformation overleaf.
Loading ...
Loading ...
Loading ...