SIGLENT
34 SDS1000CML+/SDS1000DL+ User Manual
2.8.2 Trigger Type
The scopes have five trigger types: Edge, Video, Pulse, Slope, and
Alternative.
Edge Trigger
Use Edge triggering to trigger on the edge of the oscilloscope input signal at the
trigger threshold.
Table 2-13 Edge Trigger function Menu:
Option
Setting
Explain
Type
Edge
With Edge highlighted, the rising or falling edge of
the input signal is used for the trigger.
Source
CH1
CH2
Triggers on a channel whether or not the waveform
is displayed.
EXT
Does not display the trigger signal; the Ext option
uses the signal connected to the EXT TRIG
front-panel BNC and allows a trigger level range of
-1.2V to +1.2V.
EXT/5
Same as Ext option, but attenuates the signal by a
factor of five, and allows a trigger level range of +6V
to -6V.This extends the trigger level range.
AC Line
This selection uses a signal derived from the power
line as the trigger source; trigger coupling is set to
DC and the trigger level to 0 volts.
Slope
Trigger on Rising edge of the trigger signal.
Trigger on Falling edge of the trigger signal.
Trigger on Rising edge and Falling edge of the
trigger signal.
Mode
Auto
Use this mode to let the acquisition free-run in the
absence of a valid trigger; This mode allows an
untriggered, scanning waveform at 100 ms/div or
slower time base settings.
Normal
Use this mode when you want to see only valid
triggered waveforms; when you use this mode, the
oscilloscope does not display a waveform until after
the first trigger.
Single
When you want the oscilloscope to acquire a single
waveform, press the “SINGLE ”button.
Set up
Enter the Trigger Setup Menu (See table 2-14).