Issue: The hood is making squeaking noise when it's
running.
Possible Cause: The blower fan wheel is offset to 1 side
and touching the casing or unbalanced.
Solution:
How to adjust and replace the fan wheel
Disconnect the main power.
Remove the entire hood from its mounting location.
Remove the duct and expose the blower fan wheel.
Follow these instructions to re-seat the fan wheel:
Slowly rotate the fan wheel to check which part of
it is in contact with or too close to the casing.
Rotate the fan wheel so that the blade with two
small cuts is facing you. (
Figure 4
)
Use a long screwdriver to slightly release the fixing
screw.
DO NOT remove the screw completely. It's very
difficult to put it back in.
Adjust the fan wheel left or right to the center of
the casing.
Tighten the fixing screw and plug in the hood to
the main power.
Run the hood in different speeds to check if the
issue is fixed.
Follow these instructions to replace the fan wheel
with a new one:
Remove all 4 screws holding the blower casing.
(
Figure 5
)
Take out the blower unit.
Remove all 3 screws and the side grille. (
Figure 6
)
Rotate the fan wheel and remove the fixing screw.
Take out the old fan wheel.
Align and put the new fan wheel into the casing.
Put the fixing screw back and slightly tighten it.
Adjust the fan wheel position so that it is balance
and not in contact with the casing.
Tighten the fixing screw.
Install the side grille.
Put the blower unit back into the hood and tighten
all 4 screws.
Connect to the main power and run the hood in
different speeds to check if the new fan wheel is
working properly.
RANGE HOOD TROUBLESHOOTING